CONGRATULATIONS!

In selecting this Innovative Hearth Products (IHP) electric fi replace, you have chosen 
the fi nest and most dependable fi replace found anywhere.  A beautiful and prestigious 
addition to the fi nest homes. 

Please read and carefully follow all of the instructions found in this manual.  Please pay 
special attention to the safety instructions provided in this manual.  The Homeowner's 
Care and Operation Instructions included here will assure that you have many years of 
dependable and enjoyable service from your product.

TABLE OF CONTENTS

Packaging List  ................................... page 2

Introduction  ...................................... page 2

Locating Fireplace  ............................. page 3

Tools/Supplies Required  ................... page 3

Framing Specifi cations  ...................... page 4

Fireplace Specifi cations  ..................... page 4

Clearances  ........................................ page 5

Pre-installation  .................................. page 5

Final Finishing  ................................... page 5

Break-In Period .................................. page 5

Operating Instructions  ...................... page 6

Remote Control Operation  ................ page 6

Back Glass  ........................................ page 7

LED Strip Replacement Procedure..... page 7

Product Reference Information.......... page 8

Optional Accessories  ......................... page  7

Troubleshooting  ................................ page  8

Replacement Parts  ............................ page  9

Warranty Certifi cate ........................... page 11

PACKAGING LIST

This assembled Electric Room Heater is 
packaged with:

•   One accessory package located in the 

fi rebox, containing; 

1 ea. Installation and Operation Manual.
1 ea. Remote Control

INTRODUCTION

This Electric Fireplace is designed for residen-
tial applications to be framed in as a fi replace.

This appliance has been tested in accordance 
with UL 2021 and CSA C22.2 No. 46-M198 
standards for fi xed and location dedicated 
electric room heaters.

Installation must conform to local codes. In 
the absence of local codes, electrical wiring 
and grounding must comply with the National 
Electrical Code ANSI/ NFPA 70 - latest edition.  
In Canada, the current CSA C22.1 Canadian 
Electrical Code - latest edition.

IMPORTANT:  

Before starting your fi replace 

installation, read this installation and opera-
tion manual very carefully to ensure you 
understand it completely and in entirety.  
Failure to follow these instructions may 
result in a possible electric shock, fi re 
hazard and/or injury or property damage 
and will void the warranty.

       WARNING 

If the information in this manual  
is not followed exactly, an elec-
trical shock or fi re may result 
causing property damage, per-
sonal injury or loss of life.

CAUTION: 

 Extreme caution is necessary 

when any heater is used by or near children 
or invalids and whenever the heater is left 
operating and unattended.

CAUTION: 

This appliance is mounted on 

rubber feet. The purpose of these feet is to 
ensure adequate air circulation beneath the 
fi replace. Do not remove these feet. Do not 
install the fi replace directly onto a carpet, 
rug, furniture or similar surfaces, which 
could hinder or block the airfl ow.

TO PREVENT A POSSIBLE FIRE, DO NOT 
BLOCK AIR INTAKES OR EXHAUSTS 
IN ANY WAY. DO NOT USE NEAR SOFT 
SURFACES, LIKE A PILLOW, WHERE 
OPENINGS MAY BECOME BLOCKED.

THIS APPLIANCE MAY BECOME HOT 
WHEN IN USE.  TO AVOID BURNS, DO NOT 
LET BARE SKIN TOUCH HOT SURFACES.  
KEEP COMBUSTIBLE MATERIALS, SUCH 
AS FURNITURE, PILLOWS, BEDDING, 
PAPERS, CLOTHES AND CURTAINS AT 
LEAST 3 FEET (1 METER) FROM THE 
FRONT OF THIS APPLIANCE. 

DO NOT OPERATE ANY HEATER WITH 
DAMAGED WIRING OR CONNECTORS, OR 
AFTER THE APPLIANCE MALFUNCTIONS, 
OR IF IT HAS BEEN DROPPED OR DAM-
AGED IN ANY WAY.

ANY REPAIRS TO THIS FIREPLACE 
SHOULD BE PERFORMED BY A QUALIFIED 
SERVICE TECHNICIAN.

UNDER NO CIRCUMSTANCES SHOULD 
THIS FIREPLACE BE MODIFIED.  PARTS 
HAVING TO BE REMOVED FOR SERVICING 
MUST BE REPLACED PRIOR TO OPERAT-
ING THE FIREPLACE AGAIN.

DO NOT USE THIS APPLIANCE OUT-
DOORS. DO NOT EXPOSE FIREPLACE TO 
THE ELEMENTS (SUCH AS RAIN, ETC.).

       IMPORTANT 

These fi replaces are designed 
as supplemental heaters. There-
fore, it is advisable to have an 
alternate heat source when 
installed in a dwelling.

Содержание capella 27

Страница 1: ...system and could result in an unsafe and potentially dangerous installation FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APP...

Страница 2: ...lectrical Code latest edition IMPORTANT Beforestartingyourfireplace installation readthisinstallationandopera tion manual very carefully to ensure you understand it completely and in entirety Failure...

Страница 3: ...ER CONTAINER DO NOT RUN ELECTRICAL WIRING OR POWER CORD UNDER CARPETING OR COVER WITH THROW RUGS RUNNERS OR SIMILAR MATERIALS FOR 120 VAC POWER CORD AVOID THE USE OF AN EXTENSION CORD BECAUSE THE EXTE...

Страница 4: ...installation with finish dry wall in place 11 280 mm 32 833 mm 25 635 mm 51 1 4 1302 mm 22 1 2 572 mm Corner View 4 102 mm Electrical Junction Box On Right Side 2 x 4 Electrical Junction Box 31 1 4 79...

Страница 5: ...RNING This appliance is mounted on rubber feet to ensure adequate air circulation beneath fireplace Do not block airflow at the bottom air intakes IMPORTANT Cold climate installation recom mendation w...

Страница 6: ...is a normal occurrence caused by the initial heating of the internal heating elements and should not occur again 4 FlameControlbutton Thisbuttonislocated to the left of the Temperature Button see Figu...

Страница 7: ...eandpushthemthroughtheholes in the LED strip Unclip the wires from the LED strip and remove it 6 Reinstall all components that were removed reverse Steps 1 5 Access LED strips as follows a Ember Bed L...

Страница 8: ...does not work Low batteries Unit switch and or wall switch in on position Homeowner ReplaceAAbatteriesinremotecontrol If problem persists there may have been a loss of power to the unit as a possible...

Страница 9: ...863 1 3 Glass Mirror H3864 1 4a Blower Heating Element and Access Panel Assembly H3865 1 4b Fuse Plate Assembly 5 each H5043 1 5 Flame Cylinder Assembly LED 27 H9121 1 6 Flame Motor H3867 1 7 Log Embe...

Страница 10: ...10 NOTES...

Страница 11: ...Product must be subjected to normal use All precautions and warnings as described in the instruction owner s manual must be followed c damages caused by failing to provide proper maintenance and servi...

Страница 12: ...2015 IHP reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for...