iHealth Neo BP5S Скачать руководство пользователя страница 3

3

/

14

SET UP REQUIREMENTS

The iHealth Neo Wireless Blood Pressure Monitor is designed to be used with the following iPod touch,

iPhone and iPad models:

i

iPad Air+

iPad mini+

iPad 3+

iPod Touch5

Please note that the compatible devices are subject to change. For the latest compatibility list

include Android

devices), visitwww.ihealthlabs.com/support

SET UP PROCEDURES

Download the Free iHealth MyVitals App

Prior to first use, download and install “iHealth MyVitals” from the App Store or Google Play Store. Follow the

on-screen instructions to register and set up your personal account.

Access the iHealth Cloud Account

Your iHealth account also gives you access to the free and secure iHealth cloud service. Go to www.ihealthlabs.com

and sign in with the same account.

Power on the Monitor

Press "START/STOP" button for at least 3 seconds until the LED screen display all characters to power on the monitor

at the first use.

Charge Battery before First Use

Connect the monitor to a USB port using the charging cable provided until the charging indicator full and steady.

MEASUREMENT PROCEDURES

Blood pressure can be affected by the position of the cuff and your physiologic condition. It is very important that the

cuff should be placed at the same level as your heart.

Body Posture
Sitting Comfortably During Measurement

a. Be seated with your feet flat on the floor without crossing your legs.

Содержание Neo BP5S

Страница 1: ...DICATORS 2 SET UP REQUIREMENTS 3 SET UP PROCEDURES 3 MEASUREMENT PROCEDURES 3 TAKING YOUR BLOOD PRESSURE READING 5 SPECIFICATIONS 6 GENERAL SAFETY AND PRECAUTIONS 6 BATTERY HANDLING AND USAGE 8 TROUBL...

Страница 2: ...sure measurement system It is designed to measure the systolic and diastolic blood pressures and pulse rate of an adult individual by using a technique in which an inflatable cuff is wrapped around th...

Страница 3: ...e iHealth Cloud Account Your iHealth account also gives you access to the free and secure iHealth cloud service Go to www ihealthlabs com and sign in with the same account Power on the Monitor Press S...

Страница 4: ...s measured position the monitor in the middle of your arm so that it is aligned with your middle finger When the right arm is measured position the monitor in the middle of your arm so that it is alig...

Страница 5: ...Note Please consult a health care professional for interpretation of pressure measurements BLUETOOTH FUNCTION Connect to iOS Device via Bluetooth a Enable Bluetooth on your iOS device b Launch the iH...

Страница 6: ...r storage and transport 90 RH 17 Environmental pressure 80kPa 105kPa 18 Battery life more than 130 measurements on a full charge 19 The blood pressure measurement system includes accessories pump valv...

Страница 7: ...that complies with IEC60601 1 UL 60601 1 and IEC 60601 1 2 EN 60601 1 2 such as UE05WCP 050100SPC input 100 240V 50 60Hz 0 18A output DC 5V 1 0A Please note that the monitor jack size is USB microAB...

Страница 8: ...tery low charge symbol flashing for a few seconds Do not change the battery If the battery can no longer be charged please contact Customer Service Overcharging the battery may reduce its lifetime Lit...

Страница 9: ...Bluetooth communicate error Reset monitor by pressing the START STOP button and holding for about 10 seconds then connect the mobile device correctly and try again If the monitor is still abnormal ple...

Страница 10: ...ed with Ethyl alcohol 75 90 Then air dry the cuff 8 It is recommended that product performance be checked every 2 years or after each repair Please contact the customer service Do not drop this monito...

Страница 11: ...e equipment Note This product has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable prot...

Страница 12: ...tre antenne ou metteur CE Statement The CE Mark applies to products regulated by certain European health safety and environmental protection legislation The CE Mark is obligatory for products it appli...

Страница 13: ...ent Harmonic distortion IEC 61000 3 2 Class A Home healthcare environment Voltage fluctuations and flicker IEC 61000 3 3 Compliance Home healthcare environment Table 2 Enclosure Port Phenomenon Basic...

Страница 14: ...nts burst IEC 61000 4 4 2 kV 100kHz repetition frequency Surges Line to line IEC 61000 4 5 0 5 kV 1 kV Surges Line to ground IEC 61000 4 5 0 5 kV 1 kV 2 kV Conducted disturbances induced by RF fields...

Отзывы: