!a@ ROOM TEMP.
EDIT#
!b@TIME PROGRAMS
EDIT#
Blower [$ ! 30@%
Feeding [#
!c@ WARM WATER
TEMP: 45)*
!d@ TIME DAY
12:30$ Fr#
HOUR:MINUTES
12:30
TEMP:!&@ &)21,0*
^ 18,0* = 17,0*
!e@ SEASON
WINTER)
!f@ MANUAL
$START$
TAP WATER PUMP (TW PUMP) OPERATION
TW pump starts when the boiler reaches
TW PUMP START
(H) temperature and keeps working till the container
reaches
WARM WATER
(c) temperature. The following TW pump start occurs when the container temperature
decrease is equal to
TW HYSTERESIS
(I). The pump will not start again if the boiler temperature is not
at least 5°C higher than temperature of container (protection for the container against cooling due to over-cooled
boiler).
RESETTING
The flickery arrows
! @ $
,
#
and
)
inform which button must be used to operate
MENU
and make any
resetting.
and
are for parameter changing and
MENU
navigation
and
are for
MENU
navigation
Button
enables the following returns to each previous displays till you are back on the
MAIN DISPLAY
.
If the operator makes any modifications the controller will ask if those modifications are to be entered to memory.
If there is no reaction during 1 minute, controller returns to
MAIN DISPLAY
and does not introduce any new data.
The other settings can be change after pressing
MENU:
, ,
a) room temperature for each daytime
&
-day period
^
-night period
=
-economic period
b) time programs
daytime for each day and hour daytime - hour , day (see
page 2)
c) tap water container temperature
d) hour setting display
day edition
and hour and minute setting
and active parameter selection
e) the season edition
WINTER
- central heating and tap water pumps control
SUMMER
- tap water pump control only
f) manual mode on
blower ON( )/OFF(
)
feeder ON( )/OFF(
)
and blower power increasing and decreasing
]
[
]
[