OPERATION

The boiler is fired up in 

MANUAL MODE

 (f).  To start 

MANUAL MODE

  press 

MENU

 and next  use      and      .

When the feeder is started wait till coal is delivered to retort then stop the feeder and fire up the coal. The blower can 
be used during this operation with its whole range of power. 

If there is fire in the whole retort, you can change operation mode into automatic. For this purpose press 

MENU

 and 

next    

 

 -

 

START.

 Operation status changes from 

STOP

 to 

FIRE UP

. The blower is working with its maximum 

power and the feeder delivers coal regularly.

When the 

BURNING OUT TEMPERATURE 

(M) is exceeded controller starts 

HEAT.

  

If maximum and minimum power of the blower are different the quantity of delivered air and fuel decreases (feeder 
operation time is automatically reduced) as the temperature is drawing near the value preset by user and increases as 
the temperature is drawing away. 

When the preset temperature is exceeded, the controller changes to 

HOLD

 mode. The feeder and blower begin 

periodical operation to keep fire on. Whereas, there is possibility to stop blower as in case of using the sawdust as 
solid fuel.

If the boiler temperature decreases, controller changes over to 

HEAT.

   If the boiler temperature drops below the 

value of 

BURNING OUT TEMPERATURE

 controller changes to 

STOP

 status.   However controller cannot 

change to 

STOP

, if the 

FIRE UP

 (F) time has not been completed since pressing 

START

, that is setting of 1 hour - 

made by producer.

The controller operation can be stopped at any time by pressing    

 

 -

 

STOP

.  In 

STOP

 status the blower and feeder 

are stopped.

ROOM TEMPERATURES   ROOM TEMPERATURES

 parameter (a) see page 3.

 Controller keeps up the room temperature in three daytimes accordingly;  

day period,   night period,   economy period. 

The  operator  can  set  different  room  temperature  for  each  of  these  periods.  If  the  preset  room  temperature 
is exceeded  the CH pump stops and controller changes to 

HOLD

 status.

Each day and hour can have any of those period set.

DAYTIME PROGRAM EDITION

   DAYTIME PROGRAM

 parameter(b) see page 3

 

display informs:
Monday
00:00 - 05:59 night period
06:00 - 19:59 day period
20:00 - 23:59 economic period

holding      

 

or       changes between

copy daytime and an hour selection