OPERATION
The boiler is fired up in
MANUAL MODE
(f). To start
MANUAL MODE
press
MENU
and next use and .
When the feeder is started wait till coal is delivered to retort then stop the feeder and fire up the coal. The blower can
be used during this operation with its whole range of power.
If there is fire in the whole retort, you can change operation mode into automatic. For this purpose press
MENU
and
next
-
START.
Operation status changes from
STOP
to
FIRE UP
. The blower is working with its maximum
power and the feeder delivers coal regularly.
When the
BURNING OUT TEMPERATURE
(M) is exceeded controller starts
HEAT.
If maximum and minimum power of the blower are different the quantity of delivered air and fuel decreases (feeder
operation time is automatically reduced) as the temperature is drawing near the value preset by user and increases as
the temperature is drawing away.
When the preset temperature is exceeded, the controller changes to
HOLD
mode. The feeder and blower begin
periodical operation to keep fire on. Whereas, there is possibility to stop blower as in case of using the sawdust as
solid fuel.
If the boiler temperature decreases, controller changes over to
HEAT.
If the boiler temperature drops below the
value of
BURNING OUT TEMPERATURE
controller changes to
STOP
status. However controller cannot
change to
STOP
, if the
FIRE UP
(F) time has not been completed since pressing
START
, that is setting of 1 hour -
made by producer.
The controller operation can be stopped at any time by pressing
-
STOP
. In
STOP
status the blower and feeder
are stopped.
ROOM TEMPERATURES ROOM TEMPERATURES
parameter (a) see page 3.
Controller keeps up the room temperature in three daytimes accordingly;
day period, night period, economy period.
The operator can set different room temperature for each of these periods. If the preset room temperature
is exceeded the CH pump stops and controller changes to
HOLD
status.
Each day and hour can have any of those period set.
DAYTIME PROGRAM EDITION
DAYTIME PROGRAM
parameter(b) see page 3
&
^
=
display informs:
Monday
00:00 - 05:59 night period
06:00 - 19:59 day period
20:00 - 23:59 economic period
holding
or changes between
copy daytime and an hour selection