background image

 

    

 

 

    

 

 

    

 

 

 

 

 

 

 

 

 

 

 

!M@ BLOWER POWER 

MIN:    30)%

!T@ FACTORY SET

  $RETURN$ 

!N@ BOILER OFF

TEMP:   35)*

!O@ FEEDER ALARM

    TIME:  5)m

!P@ FEEDER ALARM

    TEMP:100)*

!R@CH PUMP START
   SUMMER: 80)*

!S@KEEPING BOILER
    TEMP    NO)

M) Blower minimum power.

The blower power lower limit. 

 

N) The temperature limit below which controller makes the boiler OFF when 

the 

FIRE UP TIME

 is completed. 

O) The coal pushing time when the feeder alarm temperature is exceeded. (To 

prevent the flashback from the  boiler to coal container).

P)  Feeder  alarm  temperature  value.  Exceeding  this  temperature  the  feeder 

starts its operation to withdraw fire from feeder to the boiler. (To prevent 
the flashback from the boiler to coal container).

R) CH pump alarm temperature to start CH pump in SUMMER mode. When 

this temperature value is exceeded CH pump starts working to cool down 
boiler. (To avoid boiling water in the boiler).

S) Parameter informing if in case of CH pump stop due to obtaining the preset 

room temperature value,

i

)

  boiler  will  obtain  the  preset  boiler  temperature  and  keep  it  (

  on 

display)

ii)

 boiler will be in HOLD status till CH pump start (

NO

 on display)

YES

T)  Return  to  the  factory  settings.  Controller  makes  possible  the  return  to 

factory settings. After pressing         the question concerning confirmation 
of your decision will appear.

Отзывы: