M A I N O P E R A T I O N M O D E / M E N U
9
MRBP.424321.001G2 Version 1.0 15/06/2020
2
MAIN OPERATION MODE/MENU
2.1
MAIN OPERATION MODE
«
Main operation mode
»
- EMI-SSD-1M control unit operation mode displaying the following
information:
•
Current concentration value of the channel;
•
Set target gas and its measurement units;
•
Current channel number;
•
Sensor position (set in channel settings);
•
Current time;
•
New contingency icon
(disappears after new record review in the contingencies
menu);
•
Data exchange with the control unit via RS-485 icon
(disappears in 5 seconds after
data exchange with the control unit completion)
•
Archiving on SD-card mode on icon:
- SD card is not found, LED
«
ALARM
»
flashes 3 times every 2 s);
- SD card record error;
- SD card record protection enabled;
Sensor position
Channel number
Current concentra-
tion value
Contingency
Data archiving on SD-card
mode
Data exchange via RS-485
Current time
Measure-
ment unit
Gas type