31
Lock Behaviour
1st Time
2nd Time
3rd and
Consecutive Time
30 Sec
60 Sec
90 Sec
1 Min
5 Min
10 Min
Triggered
Security Alarm
Security Lockout
Security Lockout
After several incorrect PIN code, RFID or Fingerprint attempts, the corresponding entry
method will be locked out and the security alarm will be triggered.
Note: Bluetooth, multi-function button, handle and physical key, and any other unlocking
methods aside from the one locked out can be used to unlock in this mode
5 consecutive invalid PIN or RFID or Fingerprint
attempts by default (Configurable via Bluetooth)
Security Lockout
After 1 / 5 / 10 Minutes
or
Any other unlocking methods
If keypad is disabled -
single flash when keypad is triggered
If RFID is disabled -
RFID reader will not read any RFID cards
If fingeprint is disabled -
Fingerprint module will not flip open to read fingerprints
Please refer to table below.
Triggered by
Disabled By
Behaviour