46
IGBT D
IMMER
R
ACKS
Installation
& Operation
Dimmer Status (continued)
Circuit
The circuit number of each dimmer in the system.
Description
The name of each dimmer set using Dimmer Setup.
Error
Any error reported by the dimmer from the list of possible errors. Errors are as follows:
ote
: Constant Circuit Modules will show the Error message "Not Present."
Load
The load in Watts (100 watt increments). If Snapshot is enabled, the variation from the sampled load will be displayed in parentheses.
Level
The current level of the dimmer in percentage and DMX512.
Temp
The current temperature of the dimmer in degrees Celsius.
Yellow - Temperature is approaching a dangerous level.
Red - Temperature is above a safe level and the dimmer has shutdown.
Status
The current status of the dimmer.
Line
The current Line Voltage at the system.
Mod Size
The size of this dimmer module in maximum wattage.
SW Ver
The version number of the dimmer firmware.
MESSAGE
MEANING
mis-wire
Dimmer power-up diagnostics sensed a line voltage greater than 185 VRMS.
watchdog
Dimmer firmware has been restarted after a software loop took too long to execute.
supply
The dimmer’s 18V power supply has dropped below 14 volts.
overtemp
Dimmer has exceeded safe temperature and has shut down.
overload
Dimmer has detected an overload (excessive current) due to a short circuit or a load that exceeds the dimmer’s rating.
igbt
An IGBT has failed.
rom
The read-only memory checksum is incorrect.
analog
Either the voltage or the current-sensing electronics has failed.
not present
The module slot is empty or contains a Constant Circuit Module.