32
IGBT D
IMMER
R
ACKS
Installation
& Operation
RCM S
ETUP
Once installed on a PC, Guardian SE or NT will automatically discover and display a list of all Capio Plus IGBT Dimmer Racks
connected to the network on the left of its display. Once all the units have been discovered, it is possible to Save the configuration. This
will make it possible for Guardian SE or NT to detect a unit that is not responding in the future. To connect a PC to the Capio Plus
System, refer to the previous section: "Connecting a PC to the Capio Plus System."
Changes to an RCM can only be made while in the Administrative Mode. Refer to "Administrative Mode" on page 40. Select the
required RCM from the RCM list at left and use the RCM Setup tab to configure.
: Unlike the other configuration tabs, the data on this page is sent to the system only when the Send data on this page button is
pressed.
: The IP Address, Serial Number, Type and Number of Dimmers are set at the factory and can not be changed.
Enter a logical name for the Capio Plus System. Example: Ballrooms.
Location
Enter the location of the Capio Plus System. Example: Electrician Closet EC1.
If no input Hold level for
Specifies how long each dimmer will hold its current level if the DMX512 data stream is interrupted.
Enable Inputs
DMX A -- The local DMX512 input on the RCM.
DMX B -- The DMX512 data received through the Pathport® network via the Ethernet connection at the RCM.
Internal Presets -- Levels that come from the Local Presets.
Configuring RCM Using Guardian