9
iG5 User Manual
The Really-Quick-Start Guide for
Static Operation
Before First Use
Please r
ead the “
Best OPUS Practices for New and
Experienced Users
” section of this User Manual on page
It will save you time and failed jobs.
In the Field
1.
Fully charge the internal battery or attach an external
power source.
2.
Mount the receiver over the point you want to survey.
Level and measure the Instrument Height (HI), use a
fixed height tripod or range pole with Hold-a-Pole if
available. For best results: align the button panel to face
north, double-check your bubble and the instrument
height (HI.)
Record the HI, start time and point description in your
field notes:
3.
Push the ON/OFF button and hold it for 1-second until
the lights flash. After 30 seconds the blue LED will flash
once for every tracked Satellite.
4.
Verify that the yellow
‘
Files
’
LED flashes once every 1-
second as the receiver logs data.
5.
Let the receiver record data for at least:
OPUS-Rapid Static:
16-minutes
OPUS-Static:
121-minutes
6.
Turn the receiver off by pushing and holding the
ON/OFF button for 1-second.
Office / Desktop
1.
Install the download tool from the included thumbdrive
or get the latest version from www.iGGPS.com.
2.
Turn on the receiver, wait 10-seconds for the power LED
to flash and then plug your iG5 into a USB connector on
your computer.