18
8 Operating modes
The different operating modes of the OY95xS series safety light grids can be set
via the respective connections on the 8-pole plug of the receiver.
Operating modes
Connections
pin 4
pin 5
pin 6
A
Automatic
K1_K2
Connects to:
L- (0 V DC)
SEL_A
Connects to:
OSSD1 (pin 1)
SEL_B
Connects to:
OSSD2 (pin 3)
6
8
5
L+ L
4
1
3
B
Automatic with monitoring of
the feedback contacts
K1_K2
Connects to:
L+ (24 V DC)
(via NC of
the feedback
contacts)
SEL_A
Connects to:
OSSD2 (pin 3)
SEL_B
Connects to:
OSSD1 (pin 1)
6
8
5
L+ L
4
3
1
C
Manual
K1_K2
Connects to:
L- (0 V DC)
SEL_A
Connects to:
L+ (24 V DC)
SEL_B / Restart
Connects to:
L+ (24 V DC)
(via start button)
6
4
8
5
L+ L
D
Manually with monitoring of
the feedback contacts
K1_K2
Connects to:
L+ (24 V DC)
(via NC of
the feedback
contacts)
SEL_A / Restart
Connects to:
L+ (24 V DC)
(via start button)
SEL_B
Connects to:
L+ (24 V DC)
5
4
8
6
L+ L
1: Feedback contact 1 2: Feedback contact 2
3: Restart