OMH551 OMH553 OMH555
Photoelectric distance sensor
22
13 Factory setting
IO-Link parameter
Parameter function
Setting range
Factory setting
Own setting
[P-n]
Output polarity
[PNP]
[NPN]
PNP
[Mode]
Operating mode
[Standard]
[Power]
[Speed]
Standard
[SSC1.1 Param Sp1]
Switch point 1
(3000 ... 8000) * 0.01
(OMH551)
(5000 ... 20000) * 0.01
(OMH553)
(500 ... 5000) * 0.1
(OMH555)
8000 (OMH551)
20000 (OMH553)
5000 (OMH555)
[SSC1.1 Param Sp2]
Switch point 2
(3000 ... 8000) * 0.01
(OMH551)
(5000 ... 20000) * 0.01
(OMH553)
(500 ... 5000) * 0.1
(OMH555)
3000 (OMH551)
5000 (OMH553)
500 (OMH555)
[SSC1.1 Config Logic]
Switching output logic
0: [High active]
1: [Low Active]
0
[SSC1.1 Config Mode]
Switch point operating
modes
0: [Deactivated]
1: [Single Point]
2: [Window]
3: [TwoPoint]
1
[SSC1.1 Config Hyst]
Hysteresis
(10...500) * 0.01
(OMH551)
(10…500) * 0.01
(OMH553)
(10…500) * 0.1
(OMH555)
20 (OMH551)
20 (OMH553)
20 OMH555)
[SSC1.2 Param Sp1]
Setpoint 1
(3000 ... 8000) * 0.01
(OMH551)
(5000 ... 20000) * 0.01
(OMH553)
(500 ... 5000) * 0.1
(OMH555)
8000 (OMH551)
20000 (OMH553)
5000 (OMH555)
[SSC1.2 Param Sp2]
Switch point 2
(3000 … 8000) * 0.01
(OMH551)
(5000 ... 20000) * 0.01
(OMH553)
(500 ... 5000) * 0.1
(OMH555)
3000 (OMH551)
5000 (OMH553)
500 (OMH555)
[SSC1.2 Config Logic]
Switching output logic
0: [High active]
1: [Low Active]
0
[SSC1.2 Config Mode]
Switch point operating
modes
0: [Deactivated]
1: [Single Point]
2: [Window]
3: [TwoPoint]
1
[SSC1.2 Config Hyst]
Hysteresis
(10...500) * 0.01
(OMH551)
(10...500) * 0.01
(OMH553)
(10…500) * 0.1
(OMH555)
20 (OMH551)
20 (OMH553)
20 OMH555)
[SSC1.1 Switch-on de-
lay]
Switch-on delay
(0 ... 10000) * 0.001
0
[SSC1.1 Switch-off de-
lay]
Switch-off delay
(0 … 10000) * 0.001
0