10.3.4 Set switching delays [dSx] for the switching outputs
►
Select [dSx] and set the value between 0.0 and 60 s.
The switching delay reacts according to VDMA.
dS1
...
dS4
10.3.5 Set switch-off delay [drx] for switching outputs
►
Select [drx] and set the value between 0.0 and 60 s.
The switching delay reacts according to VDMA.
dr1
...
dr4
10.3.6 Define switching logic [P-n] for the outputs
►
Select [P-n] and set [PnP] or [nPn].
P-n
10.3.7 Define response of the outputs in case of a fault [FOUx]
►
Select [FOUx] and set value:
FOU1
...
FOU4
[On] = Output switches ON in case of a fault.
[OFF] = Output switches OFF in case of a fault.
A fault is for example: defective hardware, signal quality too low. Overflow is
not considered to be a fault
.
10.3.8 Configure display [diS]
►
Select [diS] and set value:
diS
On
The display is switched on in the operating mode.
Update of the measured values every 500 ms.
[OFF] = The display is switched off in the operating mode. When one of
the buttons is pressed, the current measured value is displayed
for 30 s. The indicator LEDs remain on even if the display is
deactivated.
10.3.9 Reset all parameters to factory settings [rES]
►
Select [rES].
►
Press and hold [Set] until [----] is displayed.
►
Briefly press [Mode/Enter].
> The unit reboots and the factory settings are restored.
rES