background image

Process and dialogue module ecomatDisplay CR1058, CR1059

28

ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen We reserve the right to make technical alterations without prior notice!

17�09�2020

CR1058 / page 4

CR1058

Technical data

Control systems

Test standards and regulations

CE mark

EN 61000-6-2

Electromagnetic compatibility (EMC)

Noise immunity

EN 61000-6-4

Electromagnetic compatibility (EMC)

Noise emission

E1 mark

UN/ECE-R10

Noise emission 

Noise immunity with 100 V/m

ISO 7637-2

Pulse 1, severity level: IV; function state C

Pulse 2a, severity level: IV; function state A

Pulse 2b, severity level: IV; function state C

Pulse 3a, severity level: IV; function state A

Pulse 3b, severity level: IV; function state A

Pulse 4, severity level: IV; function state A

Pulse 5, severity level: III; function state C

data valid for the 24 V system

Pulse 4, severity level: IV; function state A

(data valid for the 12 V system)

Additional automotive tests

ISO 10605

DIN EN ISO 13766-1

ESD (330 pF / 2000 Ω)

± 4 kV contact discharge; function state A

± 6 kV contact discharge; function state C

± 8 kV air discharge; function state C

Climatic tests

EN 60068-2-30

Damp heat, cyclic

Upper temperature 55 °C, number of cycles: 6

EN 60068-2-78

Damp heat, steady state

Test temperature 40 °C / 93 % RH

Test duration: 21 days

EN 60068-2-52

Salt spray test

Severity level 3 (vehicle)

Mechanical tests

ISO 16750-3

Test VII; vibration, random

Mounting location: vehicle body

EN 60068-2-6

Vibration, sinusoidal

10���500 Hz; 0�72 mm/10 g; 10 cycles/axis

ISO 16750-3

Bump

30 g/6 ms; 24,000 shocks

Tests for railway applications

EN 50155 clause 12�2 Mechanical/climatic tests
EN 50121-3-2

EMC emission standard and immunity
Additional information and restrictions on request

Chemical resistance

ISO 16750-5

AA, BA, BD, CC, DB, DC, DD, ED,

only one chemical permitted at a time

Содержание ecomatDisplay CR1058

Страница 1: ...Installation instructions Process and dialogue module ecomatDisplay CR1058 CR1059 80289590 00 09 2020 UK ...

Страница 2: ...l mounting control cabinet installation 10 4 3 2 Integration with installation kit 12 4 3 3 Panel cut out 12 4 3 4 Mounting steps 13 4 4 Surface mounting with RAM Mount system 14 4 4 1 Mounting steps 15 4 5 Other installation types 15 5 Electrical connection 16 5 1 Wiring 16 5 2 Connection accessories 17 5 3 Connection technology 17 5 4 General wiring information 18 5 5 Operating voltage and fuses...

Страница 3: ...7 8 1 Battery change 37 8 2 Cleaning the display surface 38 8 3 Cleaning the housing surface 39 8 4 Repair 39 8 5 Disposal 39 9 Approvals standards 39 This document is the original instructions Licences and trademarks All trademarks and company names used are subject to the copyright of the respective companies ...

Страница 4: ...ction Reaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or interference Information Supplementary note WARNING Warning of serious personal injury Death or serious irreversible injuries may result CAUTION Warning of personal injury Slight reversible injuries may result NOTE Warning of damage to property ...

Страница 5: ...t be suitable for the corresponding applications and environmental conditions without any restrictions Only use the product for its intended purpose 3 Functions and features If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur In case of malfunctions please contact the manufacturer Tampering with the unit is not allowed Installa...

Страница 6: ...h supply from SELV PELV in accordance with the technical data also in wet environments also outdoors if necessary with additional UV protection Communication with other system components e g decentralised I O modules is handled via CAN Ethernet and USB interfaces Together with the Linux operating system they form a universal platform for networking and communication with other CAN devices networks...

Страница 7: ...ng system CAN interfaces with CANopen and SAE J1939 protocol Ethernet and USB interfaces 3 3 Distinctive features CR1058 CR1059 Touch screen Freely programmable backlit buttons 4 4 Navigation keys with button 1 1 Ethernet interfaces 1 1 CAN interfaces 2 4 ifm plug play CAN based 1 USB 2 0 interfaces 1 1 Analogue video inputs 2 Digital inputs BL 2 Digital outputs 2 5 A 2 Line In Speaker output 1 1 ...

Страница 8: ... The system creator is responsible for ensuring compliance with the requirements concerning mounting of the device in the application with regard to shock vibration acceleration and weight The unit front withstands shock up to IK07 without damage NOTE Higher shock IK07 Damage possible Protection rating and electrical protection may be impaired The system creator has to protect the device depending...

Страница 9: ... 30 1 1 4 x M5 threaded hole for RAM Mount system for the fixing profiles of the installation kit 2 pressure compensation element NOTE The device is equipped with a pressure compensation element Use of elastic materials to seal or close the associated ventilation ducts may cause damage to the device Do not use any sealing materials in the area around the pressure compensation elements ...

Страница 10: ...vice 4 3 Panel mounting control cabinet installation 4 3 1 Safety instructions for panel mounting control cabinet installation The indications for the operating temperature apply equally in front of and behind the installation level The dimensions for the control panel cut out are a basic prerequisite for the requirements concerning electrical protection fire protection and protection rating of th...

Страница 11: ...net the following requirements concerning fire protection apply When mounted in accordance with the information in chapter 4 3 the device itself meets the requirements of the IEC or DIN EN 61010 2 201 concerning a closed device with regard to protection against the spreading of fire WARNING The damping strip installation kit has no flammability rating and thus presents no fire obstacle Fire protec...

Страница 12: ...gration with installation kit The installation kit enables horizontal vertical or overhead mounting of the device in a panel cutout This type of mounting is suited for materials with a thickness from 1 to 10 mm Longer set screws have to be used for material thicknesses 10 mm They are not supplied with the mounting accessories The fixing profile spacers M5 hexagon nuts washers M5 set screws and dam...

Страница 13: ... of the spacers corresponds to the panel thickness If necessary use several spacers on top of each other Screw the fixing profile to the back of the device Tightening torque of the hexagon nuts 5 0 5 Nm NOTE Contact corrosion between the mounting screws and the housing Damage to the device Do not use copper or nickel plated materials for the bolting elements Use zinc plated screws In very corrosiv...

Страница 14: ...ith the attached connector approx 72 mm 4 4 Surface mounting with RAM Mount system Using the RAM Mount components available as accessories the dialogue unit can be used as a firmly mounted desktop unit Two balls allow a variable orientation of the unit RAM Mount components 1 Mounting arm with fastening screw 2 Mounting plate with ball Dialogue module with mounted RAM Mount system You can find more...

Страница 15: ...ording to RAM Mount indications 38 1 5 56 62 6 38 1 30 5 3 Mounting plate with ball Hole dimensions Tightening torque 5 0 5 Nm Slightly loosen the fastening screw of the mounting arm Place the mounting arm onto the balls and tighten the fastening screw 4 5 Other installation types Permissible installation types 4 3 Panel mounting control cabinet installation 4 4 Surface mounting with RAM Mount sys...

Страница 16: ...e required separation from other circuits 5 1 Wiring Wiring 7 Technical data Only the signals indicated in the technical data or on the device label may be supplied to the terminals Unconnected connector pins need to have sealing of the individual cores NOTE Reverse polarity protection is not ensured in case of supply from the power supply SELV PELV to VBB30 and VBB0 Reverse polarity protection is...

Страница 17: ...the M12 connector vertically so that the coupling nut will not damage the thread Unused sockets are equipped with protective caps included Tightening torque 1 3 0 1 Nm Use 40 pole connector with individually sealed cores to ensure protection rating IP 67 Only connect the connector when the supply voltage is disconnected No hot plugging is permitted Hot plugging is permitted at the USB type A conne...

Страница 18: ... the device applies to the operating voltage connections A short circuit between operating voltage VBBX and USB audio video may cause damage to the device Lay supply and signal cables away from the device using the shortest possible route All connected cables must be provided with a strain relief Provide all outgoing cables with a strain relief 200 mm behind the cable entry Maximum cable lengths U...

Страница 19: ... 116 89 97 110 8 16 V DC and 16 32 V DC 3 A Tfuse 120 s at max 6 25 A Terminal designation pursuant to DIN 72552 Supply cables of the inputs can be safeguarded together with the fuse for VBB15 NOTE Load dump and surge without connection of VBB0 Destruction of the device possible Always connect VBB0 even if the outputs are not used or are not available 5 6 Shield connection To ensure the protection...

Страница 20: ...age category II They are construed as TNV 1 circuits Use a shielded CAT5 cable STP Shielded Twisted Pair to EIA TIA 568 Length max 25 m The max cable length depends for example on the bus topology the selected operating mode 10 100 Mbits s or the quality of the connectors Use screened connector housings and connect the screen of the Ethernet cable to the connector housing Do not lay the Ethernet c...

Страница 21: ...l panel or in the dashboard 3 USB device Permanent connection Dialogue module USB connector Use prewired cable M12 connector B coded on USB socket type A watertight cable length 1 5 m wires twisted and screened Use only cables to USB 2 0 specification for individual wiring Keep length B as short as possible and position the USB connector in immediate vicinity to the dialogue module Length B consid...

Страница 22: ...eakers For an optimum audio output 8 Ω loudspeakers have to be used 6 Set up 6 1 General The factory setting of the device shows a demo application By means of the installed recovery app any suitable firmware version can be loaded to the device Factory settings IP adress 192 168 82 247 Subnet mask 255 255 255 0 Gateway IP address 192 168 82 1 The user is responsible for the safe function of the ap...

Страница 23: ... allows the setting of the device parameters directly via the local display or the web interface of the device Local set up is started by selecting the set up button in the App Launcher While the App Launcher is shown entering the device IP address e g 192 168 82 247 via the connected web browser takes you to the web set up After leaving the set up a project can be loaded Libraries lib are availab...

Страница 24: ...ause considerable heating up The device temperature must not exceed the maximum permissible value 7 Technical data The value provided by the internal temperature sensor can e g be used for the following actions Reducing the display brightness the self heating will decrease Warning the operator about the heating and an upcoming switch off of the display Switch off of the display NOTE Internal tempe...

Страница 25: ...ass chemically hardened and anti reflective Colours 262144 18 bits Background illumination LED life cycle 50 000 h Brightness 600 cd m can be set to 0 100 step increment 1 Contrast ratio typical 500 1 Character sets can be uploaded individually and are freely scalable preinstalled ifm ISO fonts with vehicle specific symbols Arial Courier Mechanical data Mounting variants panel mounting control panel...

Страница 26: ...tection yes in case of supply via the on board system battery Power consumption 19 W Current consumption VBB0 5 A Processor ARM dual core 64 bits 800 MHz with GPU Memory total 1 GByte RAM 2 GBytes flash non volatile memory 16 kB Interfaces CAN0 1 CAN interface 2 0 A B ISO 11898 20 Kbits s 1 Mbit s default 250 Kbits s CANopen CiA DS 301 version 4 2 CiA DS 401 version 1 4 or SAE J 1939 or free protoc...

Страница 27: ...must not exceed 72 C Brightness adaptation light sensor in the front of the device to adapt the brightness of the display and the operating elements Clock battery real time clock RTC battery buffered CR1225 3 V 48 mAh Status LED RGB LED colours and states programmable by means of the application software Operating states factory setting Colour Status Description off no operating voltage green 5 Hz l...

Страница 28: ... valid for the 24 V system Pulse 4 severity level IV function state A data valid for the 12 V system Additional automotive tests ISO 10605 DIN EN ISO 13766 1 ESD 330 pF 2000 Ω 4 kV contact discharge function state A 6 kV contact discharge function state C 8 kV air discharge function state C Climatic tests EN 60068 2 30 Damp heat cyclic Upper temperature 55 C number of cycles 6 EN 60068 2 78 Damp h...

Страница 29: ...prior notice 17 09 2020 CR1058 page 5 CR1058 Technical data Control systems Back of the unit 1 2 3 4 1 AMP connector 40 poles 2 Locator for the RAM mount system and mounting frame 3 M12 connector 5 poles 4 M12 connector 4 poles AMP connector 40 poles 116 121 114 118 117 119 113 105 97 89 106 98 90 82 M12 connector 3 4 socket B coded 5 poles socket D coded 4 poles 3 1 2 4 ...

Страница 30: ... connected SERVICE1 not connected not connected CAN0_H CAN1_H not connected not connected not connected SERVICE0 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 not connected not connected not connected not connected not connected not connected AUDIO_OUT_R AUDIO_OUT_L not connected not connected not connected not connected not connected not connected AUDIO_OUT_R AUDIO_OUT_L 114 115 1...

Страница 31: ...ation in wet conditions or with gloves Format 16 10 109 x 65 8 mm 5 diagonal Resolution 800 x 480 pixels Orientation horizontal vertical Surface glass chemically hardened and anti reflective Colours 262144 18 bits Background illumination LED life cycle 50 000 h Brightness 600 cd m can be set to 0 100 step increment 1 Contrast ratio typical 500 1 Character sets can be uploaded individually and are f...

Страница 32: ...its s 1 Mbit s default 250 Kbits s CANopen CiA DS 301 version 4 2 CiA DS 401 version 1 4 or SAE J 1939 or free protocol Raw CAN ETH0 transmission rate 10 100 Mbits s protocols TCP IP UDP Modbus TCP OPC UA Micro Embedded Device Server EtherNet IP scanner adapter USB0 USB 2 0 high speed transmission rate up to 480 Mbits s USB master operation output current per interface 500 mA Analogue video input ...

Страница 33: ...must not exceed 85 C Brightness adaptation light sensor in the front of the device to adapt the brightness of the display and the operating elements Clock battery real time clock RTC battery buffered CR1225 3 V 48 mAh Status LED RGB LED colours and states programmable by means of the application software Operating states factory setting Colour Status Description off no operating voltage green 5 Hz l...

Страница 34: ... valid for the 24 V system Pulse 4 severity level IV function state A data valid for the 12 V system Additional automotive tests ISO 10605 DIN EN ISO 13766 1 ESD 330 pF 2000 Ω 4 kV contact discharge function state A 6 kV contact discharge function state C 8 kV air discharge function state C Climatic tests EN 60068 2 30 Damp heat cyclic Upper temperature 55 C number of cycles 6 EN 60068 2 78 Damp h...

Страница 35: ...prior notice 17 09 2020 CR1059 page 5 CR1059 Technical data Control systems Back of the unit 1 2 3 4 1 AMP connector 40 poles 2 Locator for the RAM mount system and mounting frame 3 M12 connector 5 poles 4 M12 connector 4 poles AMP connector 40 poles 116 121 114 118 117 119 113 105 97 89 106 98 90 82 M12 connector 3 4 socket B coded 5 poles socket D coded 4 poles 3 1 2 4 ...

Страница 36: ...M0 CAN0_L CAN1_L CAN2_L CAN3_L not connected SERVICE1 not connected IFM0 CAN0_H CAN1_H CAN2_H CAN3_H not connected SERVICE0 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 VIDEO0_GND VIDEO1_GND not connected not connected not connected not connected AUDIO_OUT_R AUDIO_OUT_L VIDEO0_SIGNAL VIDEO1_SIGNAL not connected not connected not connected not connected AUDIO_OUT_R AUDIO_OUT_L 114 ...

Страница 37: ... 8 Maintenance repair and disposal 8 1 Battery change Battery change only be qualified personnel Before changing the battery fully separate the device from supply voltage 1 2 1 Service cover 2 Battery Replace battery when time is permanently wrong after switch on ...

Страница 38: ...sealing areas and sealing for soiling and clean if necessary Screw on service cover until end stop is reached to restore protection rating Reset system time via device set up or application see programming manual ecomatDisplay Disposal of used batteries 8 5 Disposal 8 2 Cleaning the display surface Unsuitable cleaning agents and chemicals can damage the display surface The following agents are not...

Страница 39: ...y be repaired by the manufacturer Observe the safety instructions 2 Safety instructions 8 5 Disposal Dispose of used batteries in accordance with the national environmental regulations Do not dispose of used batteries with household waste Dispose of the device in accordance with the national environmental regulations 9 Approvals standards Test standards and regulations 7 Technical data The EC decl...