ifm
Basic Device Manual AS-i ControllerE M4 Target V15
2015-10-30
Menu
Main menu [System Setup]
112
Menu tree
Description
System Setup
Firmware Update
AS-i Master 2
See update of the AS-i master 1
System Setup
Password
Prevents unauthorised changes on the controllere with a 4-
digit password.
>
Display: "Password
– 0000"
An arrow (
↑) beneath shows the digit to be edited
► Go to the next digit with [
]
► Change the digit with [▲] or [▼]
► Once again [
] after the last digit
>
Display password
► Adopt with [OK]
Abort with [ESC]
>
Return to the previous menu level
If the password has been entered correctly, the corresponding
parameter changes are possible; if the password is wrong they
are blocked.
System Setup
Factory default
► Start factory setting with [OK] (password level 3 required)
>
Safety query "Are you sure?"
► [OK]
>
Reset the controllere to the factory setting. Some changes
will only become effective after the next power-on.
>
In the process, PLC programs are not deleted.
>
The the process, fieldbus settings are not reset.
>
The password is reset to level 1.
System Setup
System Errors
System setup errors
→ page
Fehler! Textmarke nicht definiert.
>
History memory of the last system errors which must be
acknowledged
System Setup
System Specials
Special system features (password level 2 required)
System Setup
System Specials
Fall Back
Switch between
FALL BACK VNC ON and
FALL BACK VNC OFF
The menu opened by the user is automatically exited if no key
is pressed after a defined period.
System Setup
System Specials
RTS Error
Switch between
RTS ERROR ON and
RTS ERROR OFF
The display of the Rxx system messages can be deactivated
by means of this setting.
System Setup
System Specials
Bitmap Manual
>
Display of saved background images
► Scroll with the keys [▲] or [▼]
► Abort with the right key