Main menu [Slave Setup]
108
9.10
Main menu [Slave Setup]
Display or change output data or parameters of individual slaves (password level 2 required)
WARNING
Risk of personal injury! Risk of material damage to the machine/plant!
After changing the slave outputs the output values remain unchanged.
The output values only change in the following cases:
Manual new setting of the outputs via Slave Setup
Start of the PLC program - the program processes the outputs
Power off the controllere and restart
► Secure the concerned area.
► Only trained personnel is allowed to set outputs manually.
► Switch the outputs off again immediately after the end of the test.
Menu tree
Description
Slave Setup
AS-i Master 1
>
Display of the detected slave with the lowest address in
the bus
► Scroll in the addresses of the detected slaves with [▲] or
[▼]
► Select slave address with [OK]
Slave Setup
AS-i Master 1
Digital output
>
Display of current parameters of the selected slave
→ page
► Change the value of the output signal with [▲] or [▼] and
then [SET].
>
The line "Current" adopts the setup value and the change
is transferred to the outputs as long as the active PLC
program in the controllere does not process these outputs.
► Abort with [ ESC].
Slave Setup
AS-i Master 1
Parameter value
>
Display of current parameters of the selected slave
→ page
► Change the parameter value in the line "Setup" with [▲] or
[▼] and transfer it to the slave with [SET].
>
If the value or change is not allowed: "Slave data invalid"
► Abort with [ ESC].
Slave Setup
AS-i Master 1
Analogue value
>
Display of current data of the selected slave (depending
on the type of slave): analogue values
► After [OK]: