CAN KEYPAD MODULE
CPM 100
PAGE
38
Object directory
Communication profiles; index 1000 to 1FFF
Index
S-Idx
Name
Type
Default
Description
1000
0x00
device type
u32, ro
0x0000
manufacturer-specific
1001
0x00
error register
u8, ro
0x00
bit coded according to profile 301;
the following is supported:
0b 0000 0000
no error
0b x00x 000
1
generic error
0b x00
1
000x
communication error
0b
1
00x 000x
manufacturer-specific
1003
0x00
pre-defined
u8, ro
0x02
An error list with 4 entries
errorfield
is supported
0x01-4
error history
u32, ro
0x00
error occurred, coded according to the
EMCY list, the last error occurred is in
the sub index 1
1005
0x00
COB-ID u32,
rw
0x80000080
- module expects synch message
SYNC
(bit 31 = 1)
- module generates no synch message
(bit 30 = 0)
- 11-bit identifier system (bit 29 = 0)
- identifier of the synch message
1006
0x00
communication
u32, rw
0x00000000
max. time between 2 synch objects
cycle period
in µs; useful resolution = 1 ms
1008
0x00
device name
str, ro
CR1500
device designation
1009
0x00
HW Version
str, ro
x.x
hardware version
100A
0x00
SW Version
str, ro
x.x
software version
100B
0x00
Node-ID
u32, ro
read only
100C
0x00
guard time
u16, rw
0x0000
time in ms
Within this time the module expects a
"node guarding" of the system master.
If the value 0 is entered here, this
function is not supported.
100D
0x00
life time factor
u8, rw
0x00
If no "node guarding" is received for
"guard time" * "life time" , the module
generates an EMCY.
The product of "guard time" * "life
time" must be between 0 and 65535.
1010
0x00
number of
u8, ro
0x01
number of "save options"
save-options
0x01
store
u32, rw
0x02
All parameters are automatically
parameters
stored after a change.
1011
0x00
number of
u8, ro
0x01
number of "restore options"
restore-options
0x01
restore default
u32, rw
0x01
If the string "load" is entered here,
parameters
the factory default parameters are
restored and are valid after the next
reset.