RFID UHF reader
10
7.1 Voltage supply
The power supply is designed as a 4-pole M12 round connector with A-coding�
4
2
1
3
Pin
Connection
1
+ 24 V DC
2
3
GND
4
Only use power supplies with limited power for operation! The power supply
must not exceed 100 W on the secondary side�
7.2 Ethernet connection
The Ethernet connection is provided as a 4-pole M12 socket with D coding�
1
2
3
4
Pin
Connection
1
TD +
2
RD +
3
TD -
4
RD -
Only use screened cables for Ethernet connection!
7.3 Inputs and outputs that are not electrically isolated
The digital inputs and outputs of the DTE800/DTE900 are designed as two 5-pole
sockets with A coding with M12 connection thread�
3
1
2
4
5
Pin Connection
1
VCC (output for the supply of the digital outputs� Not electrically isolated�)
2
OUTPUT (switching output)
3
GND (output for the supply of the digital outputs� Not electrically isolated�)
4
INPUT (switching input)
5
Not used
The digital inputs INPUT 1 and INPUT 2 are not electrically isolated from
the operating voltage!