Compact speed monitor M18
DI604A
15
8.1.5 SSC1.x Param. SP2
Switch point 2 (only available in window mode and two-point mode):
•
2.1...24,000 pulses/min; factory setting: 2.1 pulses/min
8.1.6 SSC1.x Config. Logic
Switch-point logic:
•
high active (NC)
•
low active (NO, factory setting)
8.1.7 SSC1.x Config. Mode
Switch point mode:
•
Single point (factory setting)
•
Window
•
Two point
•
Deactivated
8.1.8 SSC1.x Config. Hysteresis
Switch point hysteresis:
•
10…30% (factory setting: 10%)
8.1.9 SSC1.x Delay. dS
Switching delay: Adjustable switch-on delay time of the output in ms
•
0…60,000 ms (factory setting: 0 ms)
8.1.10 SSC1.x Delay. dS
Switch-off delay: Adjustable switch-off delay time of the output in ms
•
0…60,000 ms (factory setting: 0 ms)
8.1.11 PrSC
Prescaler, divider to calculate the actual rpm:
•
1…99 (factory setting: 1)
8.1.12 Teach offset
Sets an offset between the switching threshold and the current process data value:
•
1…200% (factory setting: 80%)
8.1.13 TI Select
Teach selection: