IO-Link master with EtherCAT interface DataLine 4 ports IP 65 / IP 66 / IP 67
74
>
Reading and writing process data
61179
The menu page allows the process data of the IO-Link master and the connected IO-Link devices to
be read and written.
Requirements:
•
Iot-Core Visualizer has been started.
► Click on [Processdata].
>
Menu page shows the substructures of the device description that contain process data and
events.
>
The current process values are displayed.
>
Editable process data can be changed.
To change the value of a process date:
► Navigate to the required process date in the device description.
► Change the process value.
► Click on the pencil icon to save the change on the IO-Link master.
>
The changed process value is active.
► Optional: Repeat the procedure to change further process values.