Switching states: Colour codes + symbols
42271
Symbol
Colour
Description
white
No safe AS-i input slave of the safe configuration
grey
– Switch open
– code sequence already taught
red
– Switch open
– code sequence not yet taught
green
– Switch closed
– code sequence taught
– transferred code sequence is identical with taught code sequence
>
Meaning of the colour combinations
42290
Symbol
Colour
Description
grey
grey
– switches S1 and S2 are open
– the two code half-sequences have been taught
grey
green
– switch S1 is open, code half-sequence has been taught
– switch S2 is closed, code half-sequence has been taught
green
grey
– switch S1 is closed, code half-sequence has been taught
– switch S2 is open, code half-sequence has been taught
green
green
– switches S1 and S2 are closed
– the two code half-sequences are identical with the taught CODE half-sequences
red
green
– switch S1 is open, code half-sequence has not been taught yet
– switch S2 is closed, code half-sequence has been taught
green
red
– switch S1 is closed, the code half-sequence has been taught
– switch S2 is open, the code half-sequence has not been taught yet
red
red
– switches S1 and S2 are open
– the two code half-sequences have not been taught yet
>
Optional: change settings of the safe AS-i input slaves
42322
To change the settings of the selected safe AS-i input slaves:
►
Use the arrow keys to mark the safe AS-i input slave.
►
Use [Select] to activate the marked AS-i slave.
>
Setting options of the selected safe AS-i input slave are displayed.
►
Change the settings as requested.
For information about the settings of the safe AS-i slaves:
→
AS-i 1 / AS-i 2: AS-i slaves
(
►
Use [Back] to return to the display of the diagnostic data.