17
UK
4:
Programming
button
[ENTER]
Selection of the parameters and acknowledgement of the
parameter values�
5:
Programming
button [Up]
Setting of the parameter values (scrolling by holding pressed;
incrementally by pressing once)�
6:
Programming
button [Down]
Setting of the parameter values (scrolling by holding pressed;
incrementally by pressing once)�
8 Set-up
►
After installation, electrical connection and programming, check whether the
unit operates correctly�
> If the unit has been correctly set up, the sensor starts with the "Guided Teach"
� The settings made last are internally stored by the sensor�
When the sensor is switched on for the first time after a reset, it will also
start with the "Guided Teach", as the taught reference profile is deleted in
case of a reset�
Lifetime of a laser diode: 50000 hours�
After successful teaching, the sensor should not be moved again� Any
change of the sensor position will lead to the taught reference profile not
being recognised reliably�The sensor must be taught again if it has been
moved�
The sensor needs a warm-up period of ≥ 10 min.The performance
parameters specified in the data sheet only apply after this warm-up period�
The teaching of objects should also be done in the warmed-up state�