12
5 Installation
5.1 Installation conditions
►
Install the unit so that the object to be detected is within the sensor's detection
zone�
►
For direct installation, fix the unit using two M4 screws�
Further accessories → www.ifm.com → Data sheet → Accessories.
5.2 Installation instructions
5.2.1 Lateral inclination
1
1: dead zone due to
shadowing
Fig� 4
The sensor should be aligned as vertically as possible to the object to be detected�
In case of lateral inclination (→ Fig. 4) and vertical object edges, the laser line will
be partially interrupted� The profile cannot be detected in this area� You can avoid
this by reducing the inclination angle�