16
Complementary outputs transmit the same sensor information with
oppositional logic levels� This means that both an NC and NO switching
output are available at the same time�
OUT1 can e�g� be used for the detection of good parts, OUT2 for the
detection of bad parts�
6.1 Operation with IO-Link master
The unit is compatible with IO-Link master port class A (type A)�
For operation with IO-Link master port class B (type B) observe the
following:
As a standard, the unit is not compatible with master port class B (type B)�
Pin 2 and pin 5 are used for manufacturer-specific functions� That means
that the main supply voltage of the unit and the additional voltage supply
(master port class B on pins 2/5) are not electrically isolated�
With the following configuration the unit can be used with master port class B:
• Connect unit and IO-Link master via 3 wires: Connect pins 1, 3 and 4 of the
unit with the IO-Link master (do not connect pins 2 and 5)�
7 Operating and display elements
1
2
3
4 5
6
1:
1x LED yellow
Switching status OUT1
2:
1 x LED green
Active LED = power
3:
Graphic display
Display of the measured matching value�