15
UK
6 Electrical connection
The unit must be connected by a qualified electrician�
►
The national and international regulations for the installation of electrical
equipment must be adhered to�
►
Ensure voltage supply to EN 50178, SELV, PELV� OPD100: cULus,
supply class 2
►
Disconnect power�
►
Connect the unit as follows:
OPD100 PNP/NPN
4
2
1
3
5
L
1
2
4
5
3
OUT2
OUT1
IN1
L+
Core colours of ifm sockets:
1 = BN (brown), 2 = WH (white), 3 = BU (blue), 4 = BK (black), 5 = GR (grey)�
Pin
Continuous mode (factory setting)
Triggered mode
1
VDD
VDD
2
OUT2 = switching output
OUT2 = ready signal (switching output)
3
GND
GND
4
OUT1 = switching output / IO-Link
OUT1 = switching output / IO-Link
5
trigger input of the PLC
trigger input of the PLC
In the operating mode "Continuous mode", OUT1 and OUT2 are configured
as complementary switching outputs�
In the operating mode "Triggered mode", OUT2 is configured as ready
�