6
4 Function
4.1 Process measured signals
The unit displays the current process values�
It generates 2 output signals according to the parameter setting�
OUT1: 4 selection options
Parameter setting
-Switching signal for volumetric flow quantity limit value
-or switching signal for flow velocity limit value
-or pulse signal for quantity meter
-or switching signal for preset counter
OUT2: 6 selection options
Parameter setting
-Switching signal for volumetric flow quantity limit value
-or switching signal for flow velocity limit value
-or switching signal for temperature limit value
-or analogue signal for volumetric flow quantity
-or analogue signal for flow velocity
-or analogue signal for temperature
If not used as an output, OUT2 (pin 2) can instead be used
as an input for an external reset signal
4.2 Volumetric flow monitoring
The volumetric flow is monitored by a calorimetric measuring system, the meas-
ured signals are evaluated by the electronics�
The signals for measuring the volumetric flow quantity can be provided as follows:
1� Two switching signals for volumetric flow quantity limit values on output 1 and
output 2 (→ 4.5).
2� An analogue signal proportional to the volumetric flow (4���20 mA) on output 2
4.3 Consumed quantity monitoring (totaliser function)
The unit has an internal quantity meter which continuously totals the volumetric
flow quantity� The sum corresponds to the current consumed quantity since the
last reset�
• The current meter reading can be displayed�