Explanation main menu
SP1 / rP1
Upper / lower limit value for volumetric flow�
ImPS
Pulse value�
ImPR
Pulse repetition active (= pulse output) or not active
(= preset counter function)�
OU1
Output function for OUT1 (volumetric flow or consumed quantity):
- Switching signal for the limit values�
- Pulse or switching signal for quantity meter�
OU2
Output function for OUT2 (volumetric flow or temperature):
- Switching signal for the limit values�
- Analogue signal: 4-20 mA [I]�
As an alternative: configure OUT2 (pin 2) as input for external reset signal:
Setting: [OU2] = [InD]�
SP2 / rP2
Upper / lower limit value for volumetric flow or temperature�
ASP2 / AEP2 Analogue start value / analogue end value for volumetric flow or temperature�
DIn2
Configure the input (pin 2) for meter reset�
EF
Extended functions / opening of menu level 2�
* The parameters are only displayed when selected at OU1�
** The parameters are only displayed when selected at OU2�
sfc = current meter reading in standard cubic feet
sfc* = stored meter reading in standard cubic feet