4. Setting of the switching parameters
Set the parameters in the following order:
Setting values
for
OP
56
Press until the requested
parameter is displayed.
Mode/Enter Set
Press and hold until the
requested value is
indicated.
Mode/Enter Set
Confirm / return to the
menu.
Mode/Enter Set
LK1222
cm
inch
6.9
2.7
8.2
3.2
9.4
3.7
10.6
4.2
11.8
4.7
13.0
5.1
14.3
5.6
15.5
6.1
16.7
6.6
17.9
7.1
19.1
7.5
20.4
8.0
LK1223
cm
inch
13.9
5.5
16.3
6.4
18.8
7.4
21.2
8.3
23.6
9.3
26.1
10.3
28.5
11.2
31.0
12.2
33.4
13.1
35.8
14.1
38.3
15.1
40.7
16.0
LK1224
cm
inch
20
8.0
24
9.5
28
10.9
31
12.3
35
13.8
39
15.2
42
16.7
46
18.1
50
19.5
53
21.0
57
22.4
61
23.9
OP
Overflow switch point
: position of the measuring segment
used as overflow protection.
Please observe the installation instructions and the indicated
minimum distances, especially the distance between OP and
the medium (
→
page 52, 57).
Switch point
: upper limit value at which the operating output
changes its switching status.
SP1
rP1
Reset point
: lower limit value at which the operating output
changes its switching status.
OU1
Switching function
for the operating output: 4 settings can be
selected: hysteresis (
H..
) or window function (
F..
), as
normally open (
.no
) or normally closed (
.nc
).
dr1
Switch-off delay
for the operating output (only for hysteresis
function), setting range: 0 ... 5 s in steps of 0.2 s.
Содержание Efector 160 LK1222
Страница 16: ...16 Zulassung nach WHG...
Страница 17: ...17 DEUTSCH Zulassung nach WHG...
Страница 18: ...18 Zulassung nach WHG...
Страница 19: ...19 DEUTSCH Zulassung nach WHG...
Страница 20: ...20 Zulassung nach WHG...
Страница 21: ...21 DEUTSCH Zulassung nach WHG...
Страница 22: ...22 Zulassung nach WHG...
Страница 23: ...23 DEUTSCH Zulassung nach WHG...
Страница 49: ...49 DEUTSCH ifm electronic gmbh Z 65 13 392...
Страница 74: ...74 30 5 64 M12 x1 I 1 L 16 50 51 8 5 A 2 1 3 I 2 Ma zeichnung Scale drawing Dimensions...