Hno
= hysteresis / NO
-
Hnc
= hysteresis / NC
-
Fno
= window function / NO
-
Fnc
= window function / NC
For specially long pump cycles a switch-off delay (
dr1
) of up to 5 s
can be additionally set (only for hysteresis function).
• b) The
overflow output
OUT-OP works as an
independent over-
flow protection
. For safety reasons it is fixed to NC (normally
closed principle). It is continuously monitored for its function.
A measuring segment of the sensor probe is selected as overflow
protection point OP (
→
page 56) and assigned to the output OUT-
OP. As soon as OP responds the overflow output opens and the
operating output is switched according to its configuration in the
same way as for the "full" state.
• The zone between tank bottom and lower edge of the measuring
probe can be entered as
offset value (OFS)
. Thus display and
switch points refer to the real level.
• The sensor can be adjusted to the medium used (
→
page 55).
• Wave movements of the medium are smoothed.
•
Display
of the current level, unit cm (
) or inch (
).
Restriction of the application area
• The sensor is not suitable for extremely conductive and adhering
media, granulates and bulk materials, acids and alkalis. It is not suit-
able for food and electroplating applications.
• The sensor is not suitable for use in grinders.
• It is possible that foam of good conductivity is detected as level.
Check the effects in your application.
• For water and hydrous media with temperatures > 35°C the unit
must be mounted into a climatic tube (order no. E43100, E43101,
E43102).
51
ENGLISH
Содержание Efector 160 LK1222
Страница 16: ...16 Zulassung nach WHG...
Страница 17: ...17 DEUTSCH Zulassung nach WHG...
Страница 18: ...18 Zulassung nach WHG...
Страница 19: ...19 DEUTSCH Zulassung nach WHG...
Страница 20: ...20 Zulassung nach WHG...
Страница 21: ...21 DEUTSCH Zulassung nach WHG...
Страница 22: ...22 Zulassung nach WHG...
Страница 23: ...23 DEUTSCH Zulassung nach WHG...
Страница 49: ...49 DEUTSCH ifm electronic gmbh Z 65 13 392...
Страница 74: ...74 30 5 64 M12 x1 I 1 L 16 50 51 8 5 A 2 1 3 I 2 Ma zeichnung Scale drawing Dimensions...