3. Technical data
ENGLISH
CAN
MEM
CR3101
31
e.g. parameter setting of mobile machines and installations
storage of remote diagnostic data or alarm and error messages
aluminium
117.5 x 85 x 35 mm
with mounting bracket
(prepared mounting bores on the sides,
see mounting variants)
IP 65
-20 ... +80 °C (memory card depending on the type)
-40 ... +80 °C (memory card depending on the type)
250 g
10...30 V DC
supply via M12 plug
120 mA (at 24 V DC)
CAN interface 2.0 B, ISO 11898
M12 plug for operating voltage and CAN bus, 5 pins (type Lumberg)
CAN electrically separated
20 Kbits/s...1 Mbits/s (default setting 125 Kbits/s)
CANopen, CiA DS 301 version 3.0
hex 20 (= 32)
USB type mini B (female)
(for PC communication, configuration and firmware update)
Secure Digital (SD) or Multi Media Card (MMC)
for SRAM PC card type I up to 16 Mbytes (preferably 1 Mbyte)
enables exact data evaluation by time stamp,
e.g. for use as error memory or crash recorder (black box)
Memory card error (CARD ERROR)
Memory card access (CARD ACCESS)
Operating voltage (ON)
Communication fault (ERROR)
CAN mode (CAN)
117,5
5 LED
CARD ERROR
CARD ACCESS
ON
ERROR
CAN
M1
2
x1
130
35
85
1
5
2
4
3
\DATEN\100\DB-FORM
—
PZD/03/12/96
ifm electronic gmbh • Teichstraße 4 • 45 127 Essen
09.10.2006
CR3101
CANmem
Data memory and logger
for CANopen systems
Use of SD/MMC cards
and memory cards
to PCMCIA standard
Parameter setting
to IEC 61131
10 ... 30 V DC
We reserve the right to make technical alterations without prior notice.
CR3101 / page 1
Application
Mechanical data
Housing
Dimensions (w x h x d)
Mounting
Protection
Operating temperature (device)
Storage temperature (device)
Weight
Electrical data
Operating voltage
Current consumption
Interfaces
CAN interface
Baud rate
Communication profile
Node ID (default)
USB interface
SD/MMC slot
PCMCIA slot
Other
Integrated real-time clock
Display (status LEDs)
1) CANopen interface
2) lid
3) USB interface
4) SD/MMC slot
5) PCMCIA slot
Содержание CANMEM CR3101