4  Operating and display elements

35,5

105

25

11

4

LEDs

2

1

1:  addressing plug

2: 

Combicon connector with screw terminals (option)

5  Installation

 

Disconnect the system from power before installation�

 

Mount the module onto a 35 mm rail or fasten it onto a suitable mounting 

surface�

6  Addressing

 The address is set to 0 at the factory�

6.1  Addressing with the AC1154 addressing unit

When mounted and wired the module can be addressed with the addressing cable 

(E70213) via the integrated addressing interface.

If the slave is used in combination with a master of the new generation (version 

2.1), it is possible to select an address between 1A and 31B with the AC1154 

addressing unit�

Содержание AC2261

Страница 1: ...Operating instructions AS i module AC2261 7390952 00 08 2017 UK ...

Страница 2: ...mbols 3 2 Safety instructions 3 3 Functions and features 3 4 Operating and display elements 4 5 Installation 4 6 Addressing 4 6 1 Addressing with the AC1154 addressing unit 4 7 Electrical connection 5 8 Operation 6 9 Maintenance repair and disposal 6 ...

Страница 3: ...e Functions and features If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur The manufacturer assumes no liability or warranty for any consequences caused by tampering with the product or incorrect use by the operator Installation electrical connection set up operation and maintenance of the unit must be carried out by qualifie...

Страница 4: ...asten it onto a suitable mounting surface 6 Addressing The address is set to 0 at the factory 6 1 Addressing with the AC1154 addressing unit When mounted and wired the module can be addressed with the addressing cable E70213 via the integrated addressing interface If the slave is used in combination with a master of the new generation version 2 1 it is possible to select an address between 1A and ...

Страница 5: ...the connection terminals Do not connect the inputs I1 I4 und I I to external potential Wiring A AS i A AS i I Sensor supply 24 V I sensor supply 0 V E actuator supply 24 V E actuator supply 0 V I1 I4 switching input sensor 1 4 O1 O4 switching output actuator 1 4 O switching output actuator 0 V LEDs 1 switching status indication sensor inputs LEDs 2 AS i FAULT AUX LEDs 3 switching status indication...

Страница 6: ...cation error e g slave address 0 LED 2 Fault red flashes periphery fault e g overload or short circuit of the output LED 2 AUX green lights external voltage OK LED 3 yellow lights output switched 9 Maintenance repair and disposal The operation of the unit is maintenance free After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations ...

Отзывы: