background image

3

UK

1  Preliminary note

Technical data, approvals, accessories and further information at  

www�ifm�com�

1.1  Key to the symbols

Instructions
Important note 

Non-compliance may result in malfunction or interference�

2  Safety instructions

•  Read this document before setting up the product and keep it during the entire 

service life�

•  The product must be suitable for the corresponding applications and 

environmental conditions without any restrictions�

• 

Only use the product for its intended purpose (→ Functions and features).

•  If the operating instructions or the technical data are not adhered to, personal 

injury and/or damage to property may occur� 

•  The manufacturer assumes no liability or warranty for any consequences 

caused by tampering with the product or incorrect use by the operator�

•  Installation, electrical connection, set-up, operation and maintenance of the unit 

must be carried out by qualified personnel authorised by the machine operator�

•  Protect units and cables against damage�

3  Functions and features

•  AS-i profile S-7�A�7
• 

maximum number of modules per master: 31 (62 with AS-i master 2.1)

•  The slave can only be operated in conjunction with a version 3�0 master 

(master profile M4).

Содержание AC2261

Страница 1: ...Operating instructions AS i module AC2261 7390952 00 08 2017 UK ...

Страница 2: ...mbols 3 2 Safety instructions 3 3 Functions and features 3 4 Operating and display elements 4 5 Installation 4 6 Addressing 4 6 1 Addressing with the AC1154 addressing unit 4 7 Electrical connection 5 8 Operation 6 9 Maintenance repair and disposal 6 ...

Страница 3: ...e Functions and features If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur The manufacturer assumes no liability or warranty for any consequences caused by tampering with the product or incorrect use by the operator Installation electrical connection set up operation and maintenance of the unit must be carried out by qualifie...

Страница 4: ...asten it onto a suitable mounting surface 6 Addressing The address is set to 0 at the factory 6 1 Addressing with the AC1154 addressing unit When mounted and wired the module can be addressed with the addressing cable E70213 via the integrated addressing interface If the slave is used in combination with a master of the new generation version 2 1 it is possible to select an address between 1A and ...

Страница 5: ...the connection terminals Do not connect the inputs I1 I4 und I I to external potential Wiring A AS i A AS i I Sensor supply 24 V I sensor supply 0 V E actuator supply 24 V E actuator supply 0 V I1 I4 switching input sensor 1 4 O1 O4 switching output actuator 1 4 O switching output actuator 0 V LEDs 1 switching status indication sensor inputs LEDs 2 AS i FAULT AUX LEDs 3 switching status indication...

Страница 6: ...cation error e g slave address 0 LED 2 Fault red flashes periphery fault e g overload or short circuit of the output LED 2 AUX green lights external voltage OK LED 3 yellow lights output switched 9 Maintenance repair and disposal The operation of the unit is maintenance free After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations ...