background image

2

SRL Series

2

Specifi cations

Chapter 2

 

SPECIFICATIONS

For convenience to the user, the pertinent specifi cations are given in an 

OPERATION GUIDE

, shown in Figures 

2-1 and 2-2, affi

  xed to the case of the instrument.

SPECIFICATIONS 

Accuracy and other specifi cations: 

See Table 2-1.

Retrace:

1 Ω to 19 MΩ

: Permanent shift in resistance value 

is <2 ppm for 23°C to 0°C to 23°C cycle, and 23°C 
to 40°C to 23°C cycle

Calibration Report:

Initial SI traceable calibration data provided in 
0.5°C in cre ments for temperature range of 18°C to 
28°C as shown in Figure 2-2.

Calibration Conditions:

Three of four-wire Kelvin measurements, low 
pow er, at 23°C; two wire for 1 MΩ and over. 
Traceable to SI

Terminals:

Gold-plated, tellurium-copper, low-thermal-emf binding 
posts on standard 3/4 inch spacing. A 

GROUND

 terminal 

is provided on all units.
≤190 kΩ: four 5-way binding posts for 4-terminal  
 

         measurement

<190 kΩ: two 5-way binding posts
≥100 MΩ: two 5-way binding posts with 

GUARD

Other available terminals:

• 

DMM direct input compatibles

• 

bnc, Triax, and custom connectors

Transit Case:

Optional 

Model SRC-100

 lightweight transit case 

with handle, suitable for transporting and storing 
two units. The case provides mechanical protection 
and insulation from temperature chang es dur ing 
trans por ta tion or shipping.

Dimensions:

8.6 cm H x 10.5 cm W x 12.7 cm D (3.4” x 4.15” x 5”)

Weight:

0.73 kg (1.6 lb) 

Figure 2-1:  OPERATION GUIDE affi xed to unit

Figure 2-2:  Temperature Calibration Chart

JOS

19-Jun-2002

SRL-1

B2-9240246

N/A

1.000 003 3 

N/A

N/A

SRL-1   STANDARD RESISTOR

±2 ppm

±3 ppm

18°C to 28°C 
0.5 V

500 mA
8 ppm per year max; 2 
ppm typical.
<2 ppm for for max. 
temp. cycles.

-1.6E-07

-2.4E-08

19-Jun-2001

23.0°C

Adjustment to Nominal:

Max. Change from 23°C

value (18°C to 28°C):

Operating Temperature

Range:

Max. Voltage:

Max. Current:

Stability:

Retrace:

Date Calibrated

Temperature (°C)

Relative Humidity

Resistance R

Test Conditions

Meas. Uncertainty

By

Recommended Due

 www.ietlabs.com

IET LABS, INC.

534 Main Street, Westbury, NY 11590

800-899-8438 • 516-334-5959

(FAX) 516-334-5988

Model:

SN:

R

t

= R

23

[1 +

 α

( t - 23 ) +

β

 ( t - 23 )

2

];

   α

=

β

=

23

JOS

19-Jun-2001

1.000 003 3 

SRL-1

B2-9240246

0

-1.6E-07

-2.4E-08

3.0

2.9

2.1

1.9

2.7

2.6

2.4

2.3

3.4

3.3

3.2

3.1

3.5

3.5

3.6

3.6

3.6

3.6

3.5

1.000 002 1 

1.000 003 5 

1.000 003 5 

1.000 003 4 

1.000 003 4 

3.5

3.4

1.000 001 9 

1.000 003 3 

1.000 003 2 

1.000 003 1 

1.000 003 0 

1.000 002 9 

1.000 002 7 

1.000 002 6 

1.000 002 4 

1.000 002 3 

1.000 003 5 

1.000 003 5 

1.000 003 6 

1.000 003 6 

1.000 003 6 

1.000 003 6 

28.0

26.0

26.5

27.0

27.5

24.0

24.5

25.0

25.5

22.0

22.5

23.0

23.5

20.0

20.5

21.0

21.5

18.0

18.5

19.0

19.5

Temperature Calibration Chart

Model:

SN:

Alpha:

Report No:

Beta:

Temperature

(°C)

Deviation from

Nominal

(ppm)

Measured value at 23°C:

Date:

By:

IET LABS, INC.

• (516) 334-5959
• (800) 899-8438

• 534 Main Street, Westbury, NY 11590

Traceable to NIST

Resistance

Содержание SRL Series

Страница 1: ...ASUREMENT Email info ietlabs com TEL 516 334 5959 FAX 516 334 5988 www ietlabs com IET LABS INC SRL Series Resistance Standard Operation Manual Copyright 2022 IET Labs Inc Visit www ietlabs com for ma...

Страница 2: ...PRECISION INSTRUMENTS FOR TEST AND MEASUREMENT Email info ietlabs com TEL 516 334 5959 FAX 516 334 5988 www ietlabs com IET LABS INC...

Страница 3: ...t no charge when returned to IET Changes in this product not approved by IET or application of voltages or currents greater than those allowed by the speci cations shall void this warranty IET shall n...

Страница 4: ...ctive 2002 96 EC This product complies with the WEEE Directive 2002 96 EC marking requirements The a xed label indicates that you must not discard this electrical electronic product in domestic househ...

Страница 5: ...ions are taken Make all connections to the instrument before applying power Note the instrument s external markings described under Safety Symbols DO NOT Operate in an Explosive Atmosphere Do not oper...

Страница 6: ...USED TAKE ALL MEASURES TO AVOID ACCIDENTAL CONTACT WITH ANY LIVE COMPONENTS USE MAXIMUM INSULATION AND MINIMIZE THE USE OF BARE CONDUCTORS WHEN USING THIS INSTRUMENT Use extreme caution when working w...

Страница 7: ...ons for values 100 M 5 3 3 Thermal emf Considerations 5 3 4 Temperature Coe cient Constants 6 3 5 Environmental Conditions 6 3 5 1 Operating Temperature 6 3 5 2 Storage Temperature 6 3 6 Shipping and...

Страница 8: ...lues 190 kW 4 Table 3 1 Connections for values 190 kW 4 Figure 3 2 Connections for values 1 MW and 100 MW 4 Table 3 2 Connections for values 1 MW and 100 MW 4 Figure 3 3 Connections for values 100 MW...

Страница 9: ...s the accuracy by indicating the deviation from nominal for the operating temperature range in 0 5 C increments Because of the low temperature coe cient they require no oil or temperature bath The SRL...

Страница 10: ...5 cm W x 12 7 cm D 3 4 x 4 15 x 5 Weight 0 73 kg 1 6 lb Figure 2 1 OPERATION GUIDE affixed to unit Figure 2 2 Temperature Calibration Chart JOS 19 Jun 2002 SRL 1 B2 9240246 N A 1 000 003 3 N A N A SRL...

Страница 11: ...ppm 4 ppm 2 ppm tot 100 mW 200 mW 500 mW 4 bp s gnd 10 k SRL 10K 2 ppm 4 ppm 1 5 ppm tot 100 mW 200 mW 500 mW 4 bp s gnd 19 k SRL 19K 2 ppm 4 ppm 2 ppm tot 100 mW 200 mW 500 mW 4 bp s gnd 20 k SRL 20...

Страница 12: ...esistance Change 18 C to 28 C 3 ppm Maximum Voltage 0 5 V Maximum Current 0 5 A LO HI LO HI SENSE CURRENT GND HI INPUT HI SENSE LO INPUT LO SENSE GROUND Binding Post Function CURRENT HI Current input...

Страница 13: ...HI GROUND GUARD HI INPUT HI SENSE LO SENSE LO INPUT GROUND GUARD If no GUARD point exists on the measuring instrument it may be connected to GROUND 3 3 Thermal emf Considerations High quality gold pl...

Страница 14: ...ult the Temperature Calibration Chart provided with each unit The calculated resistance value is provided be tween 18 C and 28 C in 0 5 C increments Figure 2 2 shows an example of this table 3 5 2 Sto...

Страница 15: ...e device the following should be observed Calibration Interval General Considerations Required Equipment Calibration Procedure 4 3 1 Calibration Interval The recommended SRL Series calibration interva...

Страница 16: ...precision high stability digi tal multimeter e g Fluke 8508A along with a set of resistance stan dards for ratio mode 4 3 4 Calibration Procedure To calibrate an SRL unit proceed as follows 1 Set up t...

Страница 17: ......

Отзывы: