background image

3

RS-925D

3

Specifications

RS925D OpERa

TInG GUIDE

consuL

T insTr

ucTion mAnu

AL For Pr

oPEr insTr

umEnT oPErA

Tion

MODEL:

 RS925D

 

 

Sn:

 D5-2307704

rs-925d label.indd/01-18-2013

W

aRnInG

obser

ve 

all 

saf

ety 

 r

ules 

when 

w

or

king 

with 

high 

voltages 

or 

line 

voltages

. connect 

the 

(Gnd) 

ter

minal 

to 

ear

th 

ground 

in 

order 

to 

maintain 

the 

case 

 at 

saf

voltage

. Whene

ver 

hazardous 

voltages 

(>45 

V) 

are 

used, 

tak

all 

measures 

to 

av

oid 

accidental 

contact 

with 

an

liv

components:

 a) 

use 

maxim

um 

in-

sulation and minimiz

e the use of bare conductors

.  b) remo

ve po

w

er when adjusting s

witches

.  c) P

ost w

ar

ning signs and k

eep personnel saf

ely a

w

ay

.

IET LABS, INC.

  

www

.ietlabs.com

cA

GE codE:

 62015

• Email:

 inf

o@ietlabs

.com  • 

Tel:

 (516) 334-5959   •   800-899-8438 

  

•   F

ax:

 (516) 334-5988

 Accuracy 

 ±(20 ppm+0.5 mΩ)   At 23°C "true ohm" measurement, 30-70% RH,  absolute reading, case grounded, SI traceable No zero subtraction required 

 Minimum resistance: 

 10 mΩ ± 0.5 mΩ

; determined by the lowest settable 

position, “1”, of the 10 mΩ

/step decade 

 Resistance repeatability: 

 Better than 100 µΩ, short-term, average value 

 Environmental Conditions: 

 Operating T

emperature:  

 0°C to 55°C 

 Storage T

emperature:  

 -40°C to 70°C 

 Switch T

ype: 

 Multiple solid silver contacts; dust-tight diallyl- phthalate body

.

To allow continuous rotation, a blank position is  added on most decades. 

Resistance 

per step

Total 

decade 

resistance

Max 

current

Max

po

wer

Temperature 

coeffi

 cient

(±ppm/ºC)

p

o

wer 

coeffi

 cient

(±ppm/mW)

Stability

(±ppm/yr)

Decade positions

Resistor type

whic

he

ver applies fi

 r

st

 100 µ

 division

20 µ

 resolution 

 10 mΩ 

 2 

 NA

 

 20 

 1 

 

 20 ppm+0.5 mΩ 

Continuous

 Rheostat 

 1 m

 

 10 mΩ 

 2 

 NA

 

 20 

 1 

 11 positions "0"-"10" 

 Resistance wire 

 10 m

 

 100 mΩ 

 2 

 NA

 

 20 

 1 

 10 positions "1"-"10"

(10 mΩ

 minimum reading 

 100 m

 

 1 Ω

 

 2 

 NA

 

 20 

 1 

11 positions "0"-"10"

 1 

 

 10 Ω 

 1 

 5 W 

 20 

 0.4 

 Wirewound  hermetically sealed  low-inductance 

 10 

 

 100 Ω

 

 0.33 

 5 W 

 10 

 0.3 

 100 

 

 1 kΩ

 

 0.1 

 5 W 

 3 

 0.1 

 1 k

 

 10 kΩ 

 33 mA

 

 5 W 

 3 

 0.1 

 10 ppm

(<5 ppm typical) 

 10 k

 

 100 kΩ

 

 10 mA

 

 5 W 

 3 

 0.1 

 100 k

 

 1 MΩ 

 3 mA

 

 2,000 V peak 

 3 

 0.1 

 12 positions "0"-"1

1" 

 Wiring and s

witc

h resistance 

 NA

 

 50 µΩ/ºC 

 0.2 µΩ/W 

NA

 For Best Performance: 

 Whenever the unit has been idle, turn each switch 7-10  times both ways before using.  

This switch "break-in" 

procedure is standard metrology practice required for  best accuracy to remove any silver oxide fi

 lm on the 

contact surfaces, typically <1 mΩ. 

 Terminals: 

 Four

, 5-way

, gold-plated, tellurium-copper 

binding posts with low thermal emf and  low resistance, for four-terminal Kelvin  measurements, plus one binding post  connected to case for shielding.  Rear outputs  are available as an option. 

RS925D OpERa

TInG GUIDE

consuL

T insTr

ucTion mAnu

AL For Pr

oPEr insTr

umEnT oPErA

Tion

MODEL:

 RS925D

 

 

Sn:

 D5-1645634

rs-925d label.indd/01-18-2013

W

aRnInG

obser

ve 

all 

saf

ety 

 r

ules 

when 

w

or

king 

with 

high 

voltages 

or 

line 

voltages

. connect 

the 

(Gnd) 

ter

minal 

to 

ear

th 

ground 

in 

order 

to 

maintain 

the 

case 

 at 

saf

voltage

. Whene

ver 

hazardous 

voltages 

(>45 

V) 

are 

used, 

tak

all 

measures 

to 

av

oid 

accidental 

contact 

with 

an

liv

components:

 a) 

use 

maxim

um 

insulation 

and 

minimiz

the 

use 

of 

bare 

conductors

.  

b) 

remo

ve 

po

w

er 

when 

adjusting 

switches

.  

c) 

P

ost 

w

ar

ning 

signs 

and 

keep 

personnel 

saf

ely 

aw

ay

.

IET LABS, INC.

  

www

.ietlabs.com

cA

GE codE:

 62015

• Email:

 inf

o@ietlabs

.com  • 

Tel:

 (516) 334-5959   •   800-899-8438 

  

•   F

ax:

 (516) 334-5988

 Accuracy 

 ±(20 ppm+0.5 mΩ)   At 23°C "true ohm" measurement, 30-70% RH,  absolute reading, case grounded, SI traceable No zero subtraction required 

 Minimum resistance: 

 10 mΩ ± 0.5 mΩ

; determined by the lowest settable 

position, “1”, of the 10 mΩ

/step decade 

 Resistance repeatability: 

 Better than 100 µΩ, short-term, average value 

 Environmental Conditions: 

 Operating T

emperature:  

 0°C to 55°C 

 Storage T

emperature:  

 -40°C to 70°C 

 Switch T

ype: 

 Multiple solid silver contacts; dust-tight diallyl- phthalate body

.

To allow continuous rotation, a blank position is  added on most decades. 

Resistance 

per step

Total 

decade 

resistance

Max 

current

Max

po

wer

Temperature 

coeffi

 cient

(±ppm/ºC)

p

o

wer 

coeffi

 cient

(±ppm/mW)

Stability

(±ppm/yr)

Decade positions

Resistor type

whic

he

ver applies fi

 r

st

 100 µ

 division

20 µ

 resolution 

 10 mΩ 

 2 

 NA

 

 20 

 1 

 

 20 ppm+0.5 mΩ 

Continuous

 Rheostat 

 1 m

 

 10 mΩ 

 2 

 NA

 

 20 

 1 

 11 positions "0"-"10" 

 Resistance wire 

 10 m

 

 100 mΩ 

 2 

 NA

 

 20 

 1 

 10 positions "1"-"10"

(10 mΩ

 minimum reading 

 100 m

 

 1 Ω

 

 2 

 NA

 

 20 

 1 

11 positions "0"-"10"

 1 

 

 10 Ω 

 1 

 5 W 

 20 

 0.4 

 Wirewound  hermetically sealed  low-inductance 

 10 

 

 100 Ω

 

 0.33 

 5 W 

 10 

 0.3 

 100 

 

 1 kΩ

 

 0.1 

 5 W 

 3 

 0.1 

 1 k

 

 10 kΩ 

 33 mA

 

 5 W 

 3 

 0.1 

 10 ppm

(<5 ppm typical) 

 10 k

 

 100 kΩ

 

 10 mA

 

 5 W 

 3 

 0.1 

 100 k

 

 1 MΩ 

 3 mA

 

 2,000 V peak 

 3 

 0.1 

 12 positions "0"-"1

1" 

 Wiring and s

witc

h resistance 

 NA

 

 50 µΩ/ºC 

 0.2 µΩ/W 

NA

 For Best Performance: 

 Whenever the unit has been idle, turn each switch 7-10  times both ways before using.  

This switch "break-in" 

procedure is standard metrology practice required for  best accuracy to remove any silver oxide fi

 lm on the 

contact surfaces, typically <1 mΩ. 

 Terminals: 

 Four

, 5-way

, gold-plated, tellurium-copper 

binding posts with low thermal emf and  low resistance, for four-terminal Kelvin  measurements, plus one binding post  connected to case for shielding.  Rear outputs  are available as an option. 

Figure 2-1:

 T

ypical Operating Guide Affix

ed to Unit

Содержание RS-925D

Страница 1: ...www ietlabs com IET LABS INC Email info ietlabs com Precision instruments for test and measurement RS 925D Resistance Standard User and Service Manual Copyright 2014 IET Labs Inc Visit www ietlabs com...

Страница 2: ...ruments for test and measurement IET Model RS 925D This RS 925D is the IET Labs version of the original esi RS 925D Decade Resistance Standard The IET unit is updated and features a number of signific...

Страница 3: ...i...

Страница 4: ...ii...

Страница 5: ...ermal emf Considerations 5 4 3 Dial Setting 6 4 4 Rheostat Operation 6 4 5 Power Considerations 6 4 6 Environmental Conditions 7 4 7 Switch Conditioning 7 4 8 Meter Shunt Applications 7 4 9 Kelvin Bri...

Страница 6: ...al Operating Guide Affixed to Unit 3 Figure 4 1 Rheostat Dial 6 Figure 4 2 Rheostat Schematic 6 Figure 4 3 Kelvin Bridge Connections 7 Table 5 1 Trimming Potentiometers 11 Figure 5 1 Typical Trimmer B...

Страница 7: ...e reading The RS 925D Resistance Standard employs com pletely enclosed dust tight very low contact resistance switches They feature solid silver alloy contacts and quadruple leaf silver alloy wipers w...

Страница 8: ...1 10 ppm 5 ppm typical 10 k 100 k 10 mA 5 W 3 0 1 100 k 1 M 3 mA 2 000 V peak 3 0 1 Wiring and switch resistance NA 50 C 0 2 W NA At 23 C true ohm measurement 30 70 RH absolute reading SI traceable N...

Страница 9: ...r Decade positions Resistor type whichever applies fi rst 100 division 20 resolution 10 m 2 A NA 20 1 20 ppm 0 5 m Continuous Rheostat 1 m 10 m 2 A NA 20 1 11 positions 0 10 Resistance wire 10 m 100 m...

Страница 10: ...ard temperatures near 23 C 3 3 Repackaging for Shipment If the instrument is to be returned to IET Labs contact the Service Department at the number or address shown on the front cover of this manual...

Страница 11: ...sistance or low resistance increments are important care must be taken in connecting to the terminals of the decade box In particular to keep contact resistance to a mini mum 4 terminal connections sh...

Страница 12: ...etting in the next decade into consideration To get 1 000 for example the switches should be set to show 0 9 10 0 Since the highest decade has an additional 11 po sition resistance values of over 1 2...

Страница 13: ...connected to the current source 2 Determine the current by the ratio of the mea sured voltage to the known resistance Using the 4 terminal technique helps avoid errors caused by the voltage drops in t...

Страница 14: ...e housing 2 Remove any dust or debris using optical grade dry compressed air or a clean brush 3 Replace the housing and reattach the 4 hous ing screws The front panel should be periodically cleaned to...

Страница 15: ...follow ing models HATS LR HATS Y SRL Series The 1 and 10 transfer standards are optional and are only used to take advantage if desired of the trimmability of these two decades Precision resistance me...

Страница 16: ...TION The RS 925D front panel should be connected to the test instrument s guard point 5 4 2 Trimming Procedure To trim any resistances proceed as follows 1 Stabilize RS 925D at laboratory temperature...

Страница 17: ...er Designation All decades but 1 k Potentiometer Designation 1 k decade 1 T0 T1 2 T1 T2 3 T2 T3 4 T3 T4 5 T4 T5 6 T5 T6 7 T6 T7 8 T7 T8 9 T8 T9 10 T9 T10 11 T10 1 M steps only Table 5 1 Trimming Poten...

Страница 18: ...HARS 4000 LX 0 1 100 m step Decade Switch Assembly Not Shown HARS 4000 LX 1 1 step Decade Switch Assembly Not Shown HARS 4000 LX 10 10 step Decade Switch Assembly Not Shown HARS 4000 LX 100 100 step...

Страница 19: ......

Отзывы: