www.ies-synergy.com
User Manual
DIM016199-EN
9
5. Specification
Technical specification
Mains supplies 3-phase L1/L2/L3 + GND 3x400V
AC
(19kW)
Mains 3-phase voltage range
V
AC
400 V
AC
± 10%
Earthed electrical system
TT or TN
Frequency range
f
50/60 Hz
± 10%
Maximum input current
I
AC
32A
Max
Power Factor
PF
0,93
Nom
Efficiency
ɳ
94 %
Nom
Harmonic current @ nominal network voltage
THDi
37 %
Max
Internal AC input protection
Inrush current limitation per phase
I
INRUSH LIMIT
< 3 x I
AC
Max
Rated Current Circuit Breaker
I
BREAK
Rating
50A
typ
Breaking capacity of breaker
I
BREAK
Capacity
6kA
Max
Max earth leakage current
I
LEAKAGE
< 3,5 mA
Max
Emergency button connection
Yes
Overvoltage (IEC60664-1)
OV III
Insulation protection Class (IEC6103)
Class II
2500V
AC
Min
Internal DC Output
Output voltage
V
DC
_max
500 V
DC
Max
V
DC
_min
200 V
DC
Min
Output current
I
DC
_max
60A
(1)(2)
Max
I
DC
_min
1A
Min
Max Output Power
P
OUT
19kW
Max
Output connector (charging station side)
Swapped vehicle cable
Car Plug coupler
COMBO1 / COMBO2 / CHAdeMO / GB
Output cable length
-
4
Meters
Internal DC output protection
Hardware and software short circuit protection
Yes
Over current protection
-
100A
Over voltage protection
adjustable
+ 10 % Max
Internal over temperature protection
-
60
°C
Reverse polarity protection
Yes
DC output Contactor
Yes (2 poles)
Rated Current Fuse (output)
I
FUSE
100
A
Galvanic isolation
V
input / output
4000
V
DC
Max time for DC line discharge < 60V
T
<60V
1
s
Embedded Insulation device
Response time (tan)
< 3sec. for asymmetrical fault
< 62sec. for symmetrical fault
Self test time
At power on and every 60s during charge
Содержание Keywatt 19
Страница 1: ...UserManual Keywatt 19Trolley www ies synergy com DUM016199 EN_V002b ...
Страница 11: ...www ies synergy com User Manual DIM016199 EN 11 Compliance ...
Страница 34: ...www ies synergy com User Manual DIM016199 EN 34 Notes ...