www.ies-synergy.com
User Manual
DIM016199-EN
18
If the charger does not start:
1. Remove the cables connected to the charger.
2.
Remove the T25 fastening screws (x6) ❶ of the circuit breaker access cover.
3.
Remove the access cover ❷ to the circuit breakers ❸.
❸
❷
❶
4.
Check that the circuit breakers (3-phase input circuit breaker ❶, RCD breaker ❷ and 12/24 V supplies cir
-
cuit breaker ❸) are in upper position, if not, put them back to upper position using a flat-head screwdriver
to access the switches.
❸
❷
❶
5. Reinstall the access cover.
6. Tighten the T25 fastening screws of the circuit breaker access cover.
7. Reconnect the cables to the charger.
8. Check that the charger starts. If it is still not starting, contact the after sales service at