EN
2 - TECHNICAL INFORMATION Elite112_220_Evo_SIII
2 - Pag. 14 / 14
PHASE-2/3/4/5/6/7 CLAMP CLOSING - REMNANT REMOVAL - CLAMP OPENING AFTER
REMOVAL - CLAMP CLOSING FOR REMNANT CHECK - CLAMP OPENING AFTER
REMNANT CHECK - ZERO AXIS
5
4
4
3
2
1
0
A12M_02_028_00
When working in removal mode,
the pneumatic clamps close and
hold the bar; the bar/remnant
detection sensor checks for the
remnant presence. If the cycle is
set to removal or to bar change
advance, phases number 2, 3, 4, 5
and 6 are skipped.
Via the feeding motor, the
remnant is removed at the preset
value.
The clamps open and the remnant
falls down.
The clamps close again to make
sure that the remnant is no longer
there and test the remnant/bar
detection sensor.
The clamps open again after
checking the remnant absence.
The bar feeder performs the zero axis until the zero position sensor switches on.
3
5
6
7
8
9
4
2
1
A12M01_02_028a_00
Содержание Elite Evo Series
Страница 2: ......
Страница 4: ......
Страница 10: ......
Страница 85: ...4 HANDLING AND INSTALLATION Elite112_220_Evo_SIII EN 4 Pag 25 25 DANGER WARNING ...
Страница 114: ......
Страница 118: ...EN 6 USE AND OPERATION Elite112_220_Evo_SIII 6 Pag 4 4 ...
Страница 148: ...EN 7 BAR FEEDER MAINTENANCE Elite112_220_Evo_SIII 7 Pag 8 8 7 6 GREASING POINTS A12M_06_003_00 Grease ...
Страница 150: ......
Страница 168: ......
Страница 188: ......