The service life of the circuit breaker is 15 years.

The circuit breaker that has worked the total number of on-off cycles 

provided for by the technical conditions before the expiration of the 
warranty cannot be replaced or repaired.

Claims for the circuit breaker will not be accepted in the event of 

independent change in the design of the product by the consumer.

Service life and manufacturer's warranty  

The warranty period for the circuit breaker is 5 years from the date of sale, 

provided that the consumer observes the rules for installation, operation, 
transportation and storage.

Òàáëèöà 

/ Table 

1

 

Òàáëèöà 

/ Table 

2

 

Íàèìåíîâàíèå ïàðàìåòðà 

/ Parameter 

denomination

Çíà÷åíèå/

Value

Âûñîòà íàä óðîâíåì ìîðÿ, ì / Base 
altitude, m

2000

3000

4000

5000

Ïîïðàâî÷íûé

 

êîýôôèöèåíò

 

ðàáî÷åãî

 

òîêà

 / 

Correction factor of operating current

1

0,94

0,88

0,83

Íàèìåíîâàíèå ïàðàìåòðà 

/ Parameter denomination

Çíà÷åíèå

 

äëÿ

 

âûêëþ÷àòåëÿ

 

òèïà

 / Value for circuit breaker of 

following type

ÂÀ88-32 

ÂÀ88-35

ÂÀ88-39

ÂÀ88-40

ÂÀ

88-4

3

 

Íîìèíàëüíîå ðàáî÷åå íàïðÿæåíèå, U ,  / Rated 

e

operating voltage, U , V

e

400/690

400/690

400/690

400/690

400/690

Íîìèíàëüíàÿ

 

÷àñòîòà

 

ïèòàþùåé

 

ñåòè

Ãö

 / Rated 

frequency of the supply network, Hz

50

Íîìèíàëüíûé

 

òîê 

/ Rated current, I , A

n

125

250

400; 630

800

1250

Óñòàâêà

 

ïî

 

òîêó

 

ðåãóëèðóåìîãî

 

ðàñöåïèòåëÿ

 

ïåðåãðóçêè 

/ Current setting of the adjustable 

overload release, I , 

À

R

50 

ё

 125

100 

ё

 250

160 

ё

 400;

250 

ё

 630*

315 

ё

 800

850

 

ё

 

1250

Óñòàâêà

 

ðàñöåïèòåëÿ

 

ñâåðõòîêîâ 

/ Overcurrent 

release setting, I

m

(4 

ё

 14)

ґ

I

n

Íîìèíàëüíîå èìïóëüñíîå âûäåðæèâàåìîå 
íàïðÿæåíèå U , Â / Rated impulse withstand 

imp

voltage U , V

imp

8000

Íîìèíàëüíîå íàïðÿæåíèå èçîëÿöèè, U , Â / Rated 

i

insulation voltage, U , V

i

800

Ðàñöåïèòåëü ñâåðõòîêîâ / Overcurrent release

Ýëåêòðîííûé

 / Electronic

K

ARA

T

Содержание BA88-32

Страница 1: ...17516 1 IEK 30 690 50 004 2011 020 2011 037 2016 IEC 60947 2 3 1 15150 88 MASTER KARAT 25 60 IEC 60947 1 IEC 60947 2 2000 5000 1 50 40 90 20 IP30 14254 IEC 60529 IP00 3 IEC 60947 1 1 88 MASTER RU KAR...

Страница 2: ...2 t sd 1 5I OFF sd 35 I i OFF I p OFF 2 1 1 3 4 2I OFF R 2 t R OFF t t I R s d i KARAT...

Страница 3: ...3 2 I 1 5Isd I sd 2I R 1 t 2 R IR 2 I 40 C I R 5 7 t 1 5I sd sd 3 4 6 5 KARAT...

Страница 4: ...4 1 3 5 2 4 6 1 3 5 1 3 5 90 8 10 5 6 7 8 13983 1 5 6 6 10434 17441 KARAT...

Страница 5: ...5 23216 4 2 15150 15 25 60 5 25 60 50 40 90 20 KARAT...

Страница 6: ...ase altitude no more than 2000 m operation at the altitude of up to 5000 m is allowed with a decrease in the operating current taking into account the correction factor table 1 The electronic micropro...

Страница 7: ...tection of the circuit breaker against overcurrents The circuit breaker is not affected by temperature changes but at an ambient temperature above plus 40 C the short circuit protection setting should...

Страница 8: ...are shown in figure 7 The adapter tips are designated as For the central outlet and represent three straight copper busbars The extended terminals consist of one central and two side tires Completene...

Страница 9: ...e control handle of the circuit breaker will take the middle position The interphase baffles included in the delivery set should be installed in the corresponding grooves during the installation of ex...

Страница 10: ...rules for installation operation transportation and storage Table 1 Table 2 Parameter denomination Value Base altitude m 2000 3000 4000 5000 Correction factor of operating current 1 0 94 0 88 0 83 Par...

Страница 11: ...of fasteners for connecting external conductors See text Tightening torque of fasteners for connecting external conductors N m 10 1 12 1 28 3 28 3 12 1 Thread size of fasteners for connecting externa...

Страница 12: ...n OFF without protection 8 12 16 24 32 48 64 96 128 6 I Delayed short circuit sd protection current Isd 2 2 5 3 4 5 6 7 8 10 12 IR 8 IR 7 1 5 I t sd sd Response delay time at short circuit for curren...

Страница 13: ...1 250 1 400 630 1 800 1 1250 Electric drive 32 35 39 40 43 Mounting plate of plug in type 1 125 1 250 1 400 630 1 800 Mechanical interlock 125 250 400 630 800 Extended outputs 125 32 35 250 39 400 630...

Страница 14: ...0 3 0 75 0 8 0 7 1 0 85 0 9 0 95 In 250A T IR A tR s lsd xIR tsd s Ii xIR Ip xIR IR Isd Ii I 1 2 3 4 5 6 7 8 9 60 80 100 12 2 Figure 2 Time current characteristics of the circuit breaker Operating ti...

Страница 15: ...54 92 5 30 17 5 30 116 82 28 5 28 5 25 5 25 5 25 4 5 88 35 250 165 146 126 300 107 35 23 35 116 85 22 5 22 5 18 5 18 5 60 5 4 5 88 39 630 257 224 194 471 150 48 31 44 151 99 40 5 41 5 34 5 35 5 47 7 8...

Страница 16: ...for the switch Busbar for 88 32 88 35 88 39 88 40 Busbar for 88 43 A B D B A D 2 hole C Type Dimensions mm D 88 32 17 8 8 88 35 22 5 12 8 88 39 30 5 12 10 88 40 44 5 15 10 88 43 43 13 21 8 10 D Minimu...

Страница 17: ...uit breaker in the switchboard 1 Non insulated connection 2 Insulated cable 3 Cable lugs Type Installation in a metal grounded shield Installation in an isolated shield mm D mm mm mm mm mm mm mm 88 32...

Страница 18: ...he extended terminals and adapters for the switch Type Dimensions mm W H L D1 88 32 125 16 4 50 8 5 88 35 250 20 5 67 9 88 39 630 30 10 70 10 5 88 40 800 40 8 120 13 Type Dimensions mm D2 c a b 88 32...

Отзывы: