TANK-801 Em b e d d e d S ys te m
P a g e 55
Auto PWM Mode
The fan adjusts its speed using these
settings:
Temperature of Start
Temperature of Off
Start PWM
Slope (Duty Cycle)
Ma n u a l P WM S e ttin g
Use the + or – key to change the
Manual PWM Setting
value. Enter a decimal number
between 0 and 100.
Te m p e ra tu re o f Off [75]
WARNING:
Setting this value too high may cause the fan to speed up only when
the CPU is at a very high temperature and therefore cause the system
to be damaged.
The
Temperature of Off
option can only be set if the
Smart Fan control
option is set to
Auto PWM Mode
. When the
CPU Temperature
is lower than
Temperature of Off
, the
fan will be rotate at lowest speed. To set a value, select the
Temperature of Off
option
and enter a decimal number between 0 and 127. The temperature range is specified
below.
Minimum Value: 0°C
Maximum Value: 127°C
Te m p e ra tu re o f S ta rt [80]
WARNING:
Содержание TANK-801-BT
Страница 13: ...TANK 801 Embedded Sys tem Page 1 Chapter 1 1 Introduction...
Страница 23: ...TANK 801 Embedded Sys tem Page 11 Chapter 2 2 Unpacking...
Страница 27: ...TANK 801 Embedded Sys tem Page 15 Chapter 3 3 Ins tallation...
Страница 54: ...TANK 801 Embedded Sys tem Page 42 Chapter 4 4 BIOS...
Страница 93: ...TANK 801 Embedded Sys tem Page 81 Appendix A A Regulatory Compliance...
Страница 99: ...TANK 801 Embedded Sys tem Page 87 Appendix B B BIOS Options...
Страница 102: ...TANK 801 Embedded Sys tem Page 90 Appendix C C Safety Precautions...
Страница 107: ...TANK 801 Embedded Sys tem Page 95 Appendix D D Digital I O Interface...
Страница 110: ...TANK 801 Embedded Sys tem Page 98 Appendix E E Hazardous Materials Dis clos ure...