background image

 

 

SPCIE-C2260-i2 PICMG 1.3 CPU Card 

Page iv 

Manual Conventions 

   

 

WARNING 

Warnings appear where overlooked details may cause damage to the 

equipment or result in personal injury. Warnings should be taken 

seriously. 

 

 

CAUTION 

Cautionary messages should be heeded to help reduce the chance of 

losing data or damaging the product.   

 

 

NOTE 

These messages inform the reader of essential but non-critical 

information. These messages should be read carefully as any directions 

or instructions contained therein can help avoid making mistakes. 

 

 

HOT SURFACE 

This symbol indicates a hot surface that should not be touched without 

taking care.

 

Содержание SPCIE-C2260-i2

Страница 1: ...al MODEL SPCIE C2260 i2 Full Size PICMG 1 3 CPU Card Supports LGA1150 Intel Xeon E3 Core i3 Pentium or Celeron CPU Intel C226 Chipset DDR3 VGA iDP Dual Intel PCIe GbE SATA 6Gb s PCIe Mini mSATA RS 232...

Страница 2: ...cal Specifications Updated Section 2 4 Optional Items Updated Chapter 5 BIOS March 23 2015 1 04 Updated Section 4 3 3 Flash Descriptor Security Override Jumper November 5 2014 1 03 Updated PCIe specif...

Страница 3: ...amages arising out of the use or inability to use the product or documentation even if advised of the possibility of such damages This document contains proprietary information protected by copyright...

Страница 4: ...CAUTION Cautionary messages should be heeded to help reduce the chance of losing data or damaging the product NOTE These messages inform the reader of essential but non critical information These mess...

Страница 5: ...CONNECTORS 15 3 1 PERIPHERAL INTERFACE CONNECTORS 16 3 1 1 SPCIE C2260 i2 Layout 16 3 1 2 Peripheral Interface Connectors 17 3 1 3 External Interface Panel Connectors 18 3 2 INTERNAL PERIPHERAL CONNEC...

Страница 6: ...4 TPM Connector 42 3 2 25 USB 2 0 Connectors 43 3 2 26 USB 3 2 Gen 1 5Gb s Connector 44 3 3 EXTERNAL PERIPHERAL INTERFACE CONNECTOR PANEL 45 3 3 1 Ethernet Connectors 45 3 3 2 USB 3 2 Gen 1 5Gb s Conn...

Страница 7: ...2 Using the IEI iMAN Web GUI 68 5 BIOS 71 5 1 INTRODUCTION 72 5 1 1 Starting Setup 72 5 1 2 Using Setup 72 5 1 3 Getting Help 73 5 1 4 Unable to Reboot after Configuration Changes 73 5 1 5 BIOS Menu B...

Страница 8: ...2 NB PCIe Configuration 110 5 4 2 3 Memory Configuration 111 5 5 BOOT 112 5 6 SECURITY 114 5 7 SAVE EXIT 115 5 8 SERVER MGMT 116 5 8 1 System Event Log 117 5 8 2 BMC Network Configuration 119 6 SOFTWA...

Страница 9: ...F 3 ACCESSING THE INTEL MATRIX STORAGE MANAGER 140 F 4 INSTALLING THE OPERATING SYSTEM TO THE RAID ARRAY 141 G ERROR BEEP CODE 142 G 1 PEI BEEP CODES 143 G 2 DXE BEEP CODES 143 H HAZARDOUS MATERIALS...

Страница 10: ...3 10 System Fan Connector Location 27 Figure 3 11 Front Panel Connector Location 28 Figure 3 12 Internal DisplayPort Connector Location 29 Figure 3 13 Infrared Connector Location 30 Figure 3 14 iRIS...

Страница 11: ...e Switch Location 57 Figure 4 8 Clear CMOS Button Location 57 Figure 4 9 Flash Descriptor Security Override Jumper Location 58 Figure 4 10 mSATA Mode Selection Jumper Location 59 Figure 4 11 Dual RS 2...

Страница 12: ...ts 27 Table 3 11 Front Panel Connector Pinouts 28 Table 3 12 Internal DisplayPort Connector Pinouts 29 Table 3 13 Infrared Connector Pinouts 30 Table 3 14 Keyboard and Mouse Connector Pinouts 32 Table...

Страница 13: ...ort Pinouts 46 Table 3 32 VGA Connector Pinouts 47 Table 4 1 AT ATX Power Mode Switch Settings 57 Table 4 2 Flash Descriptor Security Override Jumper Settings 58 Table 4 3 mSATA Mode Selection Jumper...

Страница 14: ...DA Configuration Menu 92 BIOS Menu 14 Parallel Port Configuration Menu 94 BIOS Menu 15 F81866 H W Monitor 95 BIOS Menu 16 Smart Fan Mode Configuration 97 BIOS Menu 17 Serial Port Console Redirection 9...

Страница 15: ...SPCIE C2260 i2 PICMG 1 3 CPU Card Page xv BIOS Menu 31 Save Exit 115 BIOS Menu 32 Server Mgmt 116 BIOS Menu 33 System Event Log 117 BIOS Menu 34 System Event Log 119...

Страница 16: ......

Страница 17: ...SPCIE C2260 i2 PICMG 1 3 CPU Card Page 1 Chapter 1 1 Introduction...

Страница 18: ...th Intel AMT 9 0 support and the Intel I210 PCIe controllers The integrated Intel C226 chipset supports six SATA 6Gb s drives In addition the SPCIE C2260 i2 includes VGA and iDP interfaces for dual in...

Страница 19: ...dual channel DDR3 DIMMs support up to 32 GB Dual independent display by VGA and iDP interfaces Supports IPMI 2 0 via iRIS 2400 module One PCIe Mini slot with mSATA support Two Intel PCIe GbE connecto...

Страница 20: ...SPCIE C2260 i2 PICMG 1 3 CPU Card Page 4 1 3 Connectors The connectors on the SPCIE C2260 i2 are shown in the figure below Figure 1 2 Connectors...

Страница 21: ...SPCIE C2260 i2 PICMG 1 3 CPU Card Page 5 1 4 Dimensions The main dimensions of the SPCIE C2260 i2 are shown in the diagram below Figure 1 3 SPCIE C2260 i2 Dimensions mm...

Страница 22: ...SPCIE C2260 i2 PICMG 1 3 CPU Card Page 6 1 5 Data Flow Figure 1 4 shows the data flow between the system chipset the CPU and other components installed on the motherboard Figure 1 4 Data Flow Diagram...

Страница 23: ...our PCIe x1 slots Ethernet Controllers LAN1 Intel I217LM PHY with Intel AMT 9 0 support LAN2 Intel I210 PCIe Ethernet controller with NC SI support Super I O Controller Fintek F81866 EC IWDD Watchdog...

Страница 24: ...via 5 pin header IPMI 2 0 One iRIS module slot Keyboard and Mouse One 6 pin wafer connector LAN LEDs Two 2 pin headers for LAN1 LED and LAN2 LED active Parallel Port One parallel port via internal 26...

Страница 25: ...3 3V 1 55A 5VSB 0 13A 3 4 GHz Intel E3 1240 v3 CPU with four 4 GB 1333 MHz DDR3 memory Operating Temperature 20 C 60 C Storage Temperature 30 C 70 C Humidity 5 95 non condensing Physical Specification...

Страница 26: ...SPCIE C2260 i2 PICMG 1 3 CPU Card Page 10 Chapter 2 2 Packing List...

Страница 27: ...tic discharge Self grounding Touch a grounded conductor every few minutes to discharge any excess static buildup Use an anti static pad When configuring any circuit board place it on an anti static ma...

Страница 28: ...eseller or vendor the SPCIE C2260 i2 was purchased from or contact an IEI sales representative directly by sending an email to sales ieiworld com The SPCIE C2260 i2 is shipped with the following compo...

Страница 29: ...485 cable 200 mm P N 32205 003800 300 RS Dual port USB 3 2 Gen 1 cable with bracket P N 19800 010500 200 RS KB MS cable with bracket P N 19800 000075 RS SATA power cable P N 32102 000100 200 RS LPT c...

Страница 30: ...for IEI IDP connector P N DP DVI R10 DisplayPort to DisplayPort converter board for IEI iDP connector P N DP DP R10 Infineon TPM module P N TPM IN01 R20 LGA1150 cooler kit high performance compatible...

Страница 31: ...SPCIE C2260 i2 PICMG 1 3 CPU Card Page 15 Chapter 3 3 Connectors...

Страница 32: ...d Page 16 3 1 Peripheral Interface Connectors This chapter details all the peripheral interface connectors 3 1 1 SPCIE C2260 i2 Layout The figures below show all the peripheral interface connectors Fi...

Страница 33: ...ital I O connector 10 pin header DIO1 EC debug connector 18 pin header CN3 Fan connector CPU 4 pin wafer CPU_FAN1 Fan connector system 3 pin wafer SYS_FAN1 Front panel connector 14 pin header F_PANEL1...

Страница 34: ...8 pin header JSPI2 TPM connector 20 pin header TPM1 USB 2 0 connectors 8 pin header USB1 USB2 USB 3 2 Gen 1 connector 19 pin box header CN7 Table 3 1 Peripheral Interface Connectors 3 1 3 External Int...

Страница 35: ...C2260 i2 3 2 1 12V ATX Power Supply Connector CN Label CPU12V1 CN Type 4 pin Molex power connector CN Location See Figure 3 2 CN Pinouts See Table 3 3 This connector provides power to the CPU Figure...

Страница 36: ...Location See Figure 3 3 CN Pinouts See Table 3 4 This connector connects to an external audio kit Figure 3 3 Audio Connector Location Pin Description Pin Description 1 HDA_SYNC 2 HDA_BIT_CLK 3 HDA_SDO...

Страница 37: ...cal regulations CN Label BAT1 CN Type 2 pin wafer CN Location See Figure 3 4 CN Pinouts See Table 3 5 This is connected to the system battery The battery provides power to the system clock to retain t...

Страница 38: ...ion See Figure 3 5 CN Pinouts See Table 3 6 The chassis intrusion connector is for a chassis intrusion detection sensor or switch that detects if a chassis component is removed or replaced Figure 3 5...

Страница 39: ..._DIMM2 CN Type DDR3 DIMM slot CN Location See Figure 3 6 The DIMM slots are for DDR3 DIMM memory modules CAUTION For quad channel configuration always install four identical memory modules that featur...

Страница 40: ...3 7 The digital I O connector provides programmable input and output for external devices The digital I O provides 4 bit output and 4 bit input Figure 3 7 Digital I O Connector Location Pin Descriptio...

Страница 41: ...g connector is used for EC debug Figure 3 8 EC Debug Connector Location Pin Description Pin Description 1 EC_EPP_STB 2 EC_EPP_AFD 3 EC_EPP_PD0 4 NC 5 EC_EPP_PD1 6 EC_EPP_INIT 7 EC_EPP_PD2 8 EC_EPP_SLI...

Страница 42: ...r CPU CN Label CPU_FAN1 CN Type 4 pin wafer CN Location See Figure 3 9 CN Pinouts See Table 3 9 The fan connector attaches to a CPU cooling fan Figure 3 9 CPU Fan Connector Location Pin Description 1...

Страница 43: ...m CN Label SYS_FAN1 CN Type 3 pin wafer CN Location See Figure 3 10 CN Pinouts See Table 3 10 The fan connector attaches to a system cooling fan Figure 3 10 System Fan Connector Location Pin Descripti...

Страница 44: ...onnects to the indicator LEDs and buttons on the computer s front panel Figure 3 11 Front Panel Connector Location Function Pin Description Function Pin Description Power LED 1 5V Speaker 2 BEEP_PWR 3...

Страница 45: ...ctor supports HDMI LVDS VGA DVI and DisplayPort graphics interfaces with up to 3840x2160 resolution Figure 3 12 Internal DisplayPort Connector Location Pin Description Pin Description 1 5V 11 AUXP 2 L...

Страница 46: ...IR1 CN Type 5 pin header CN Location See Figure 3 13 CN Pinouts See Table 3 13 The infrared connector attaches to an infrared receiver for use with remote controls Figure 3 13 Infrared Connector Locat...

Страница 47: ...Location See Figure 3 14 The iRIS module slot allows installation of the iRIS 2400 module Figure 3 14 iRIS Module Slot Location WARNING The iRIS module slot is designed to install the iRIS 2400 module...

Страница 48: ...gure 3 15 CN Pinouts See Table 3 14 The keyboard and mouse connector connects to a PS 2 Y cable that can be connected to a PS 2 keyboard and mouse Figure 3 15 Keyboard and Mouse Connector Location Pin...

Страница 49: ...able 3 16 The LAN LED connectors are used to connect to the LAN LED indicators on the chassis to indicate users the link activities of the two LAN ports Figure 3 16 LAN LED Connector Locations Pin Des...

Страница 50: ...r interface or some other parallel port device such as a printer Figure 3 17 Parallel Port Connector Location Pin Description Pin Description 1 STROBE 2 DATA0 3 DATA1 4 DATA2 5 DATA3 6 DATA4 7 DATA5 8...

Страница 51: ...stalling a PCIe Mini expansion card Figure 3 18 PCIe Mini Card Slot Location Pin Description Pin Description 1 PCIE_WAKE 2 3 3V 3 N C 4 GND 5 N C 6 1 5V 7 N C 8 N C 9 GND 10 N C 11 MSATA_CLK 12 N C 13...

Страница 52: ...CLINK_RST 50 GND 51 MSATA_DET 52 3 3V Table 3 18 PCIe Mini Card Slot Pinouts 3 2 18 SATA 6Gb s Drive Connector CN Label S_ATA1 S_ATA2 S_ATA3 S_ATA4 S_ATA5 S_ATA6 CN Type 7 pin SATA drive connector CN...

Страница 53: ...SATA RX 7 GND Table 3 19 SATA 6Gb s Drive Connector Pinouts 3 2 19 Serial Port Connectors RS 232 CN Label COM1 COM3 COM4 COM5 CN Type 10 pin box header CN Location See Figure 3 20 CN Pinouts See Table...

Страница 54: ...CN Label COM2 CN Type 4 pin wafer CN Location See Figure 3 21 CN Pinouts See Table 3 21 This connector provides RS 422 or RS 485 communications Figure 3 21 RS 422 485 Connector Location Pin Descriptio...

Страница 55: ...MBus Connector CN Label CN2 CN Type 4 pin wafer CN Location See Figure 3 22 CN Pinouts See Table 3 23 The SMBus System Management Bus connector provides low speed system management communications Figu...

Страница 56: ...8 pin header CN Location See Figure 3 23 CN Pinouts See Table 3 24 The SPI flash connector is used to flash the SPI ROM Figure 3 23 SPI Flash Connector Location Pin Description Pin Description 1 3 3V...

Страница 57: ...pin header CN Location See Figure 3 24 CN Pinouts See Table 3 25 The SPI flash connector is used to flash the EC ROM Figure 3 24 SPI EC Flash Connector Location Pin Description Pin Description 1 3 3V...

Страница 58: ...25 CN Pinouts See Table 3 26 The TPM connector connects to a TPM module Figure 3 25 TPM Connector Location Pin Description Pin Description 1 LCLK 2 GND 3 LFRAME 4 KEY 5 LRERST 6 5V 7 LAD3 8 LAD2 9 3 3...

Страница 59: ...See Figure 3 26 CN Pinouts See Table 3 27 The USB 2 0 connectors connect to USB 2 0 devices Each pin header provides two USB 2 0 ports Figure 3 26 USB 2 0 Connector Pinout Locations Pin Description P...

Страница 60: ...Gb s connector connects to USB 3 2 Gen 1 devices This connector provides two USB 3 2 Gen 1 ports Figure 3 27 USB 3 2 Gen 1 Connector Location Pin Description Pin Description 1 VCC 11 USB_DATA 2 USB3_R...

Страница 61: ...nterface Connector 3 3 1 Ethernet Connectors CN Label LAN1 LAN2 CN Type RJ 45 CN Location See Figure 3 28 CN Pinouts See Figure 3 29 and Table 3 29 The SPCIE C2260 i2 is equipped with two built in RJ...

Страница 62: ...able 3 30 Connector LEDs 3 3 2 USB 3 2 Gen 1 5Gb s Connectors CN Label CN5 CN6 CN Type USB port CN Location See Figure 3 28 CN Pinouts See Table 3 31 The SPCIE C2260 i2 has two external USB 3 2 Gen 1...

Страница 63: ...e 3 28 CN Pinouts See Figure 3 30 and Table 3 32 The VGA connector connects to a monitor that accepts a standard VGA input Pin Description Pin Description 1 RED 2 GREEN 3 BLUE 4 NC 5 GND 6 GND 7 GND 8...

Страница 64: ...SPCIE C2260 i2 PICMG 1 3 CPU Card Page 48 Chapter 4 4 Installation...

Страница 65: ...tic wristband can help to prevent ESD from damaging the board Self grounding Before handling the board touch any grounded conducting material During the time the board is handled frequently touch any...

Страница 66: ...he body and helps prevent ESD damage Place the SPCIE C2260 i2 on an anti static pad o When installing or configuring the motherboard place it on an anti static pad This helps to prevent potential ESD...

Страница 67: ...installed DO NOT touch the pins at the bottom of the CPU When handling the CPU only hold it on the sides To install the CPU follow the steps below Step 1 Disengage the load lever by pressing the lever...

Страница 68: ...air Step 4 Orientate the CPU properly The contact array should be facing the CPU socket WARNING DO NOT touch the pins at the bottom of the CPU When handling the CPU only hold it on the sides Step 5 C...

Страница 69: ...othly See Figure 4 3 Figure 4 3 Insert the Socket LGA1150 CPU Step 8 Close the CPU socket Close the load plate and pull the load lever back a little to have the load plate be able to secure to the kno...

Страница 70: ...bending and is ONLY compatible with captive screw type cooling fans The cooling kit can be bought from IEI The cooling kit has a heat sink and fan WARNING Do not wipe off accidentally or otherwise th...

Страница 71: ...ntly place the cooling kit on top of the CPU Make sure the four threaded screws on the corners of the cooling kit properly pass through the holes of the cooling kit bracket Step 4 Secure the cooling k...

Страница 72: ...IMM Installation Step 1 Open the DIMM socket handles Open the two handles outwards as far as they can See Figure 4 6 Step 2 Align the DIMM with the socket Align the DIMM so the notch on the memory lin...

Страница 73: ...ower mode switch which is shown in Figure 4 7 Figure 4 7 AT ATX Power Mode Switch Location Setting Description 1 2 down ATX power mode default 2 3 up AT power mode Table 4 1 AT ATX Power Mode Switch S...

Страница 74: ...Security Override Jumper Settings Figure 4 9 Flash Descriptor Security Override Jumper Location To update the ME firmware please follow the steps below Step 1 Before turning on the system power short...

Страница 75: ...cation 4 3 5 PCIe x16 Interface Setup The SPCIE C2260 i2 supports one PCIe x16 interface on the backplane The PCIe x16 interface setup is made through the BIOS menu in Chipset PCH IO Configuration Use...

Страница 76: ...1 ports Table 4 5 BIOS Options and Configured USB Ports Options Description 5V DUAL 5V dual default 5V 5V Table 4 6 USB Power Source Setup Please refer to Section 5 4 1 for detailed information 4 4 C...

Страница 77: ...of peripheral devices to the onboard connectors 4 5 1 Dual RS 232 Cable with Slot Bracket The dual RS 232 cable slot connector consists of two connectors attached to two independent cables Each cable...

Страница 78: ...RIS 2400 module only DO NOT install other modules into the iRIS module slot Doing so may cause damage to the SPCIE C2260 i2 To install the iRIS 2400 module please follow the steps below and refer to F...

Страница 79: ...for IPMI setup procedures 4 5 3 SATA Drive Connection The SPCIE C2260 i2 is shipped with two SATA drive cables To connect the SATA drives to the connectors please follow the steps below Step 1 Locate...

Страница 80: ...ATA power connector to the back of the SATA drive See Figure 4 14 Step 0 Figure 4 14 SATA Power Drive Connection 4 5 4 USB Cable Dual Port with Slot Bracket The SPCIE C2260 i2 is shipped with a dual p...

Страница 81: ...0 i2 connect the cable connectors to the on board connectors See Figure 4 15 Figure 4 15 Dual USB Cable Connection Step 4 Attach the bracket to the chassis The USB 2 0 connectors are attached to a bra...

Страница 82: ...ews for the PCIe Mini Card Step 3 Insert into the socket at an angle Line up the notch on the card with the notch on the connector Slide the PCIe Mini card into the socket at an angle of about 20 Figu...

Страница 83: ...cable to the RJ 45 connector labeled LAN1 Step 3 The AMI BIOS options regarding the Intel ME or Intel AMT must be enabled Step 4 Properly install the Intel Management Engine Components drivers from th...

Страница 84: ...7 1 Managed System Hardware Setup The hardware configuration of the managed system SPCIE C2260 i2 is described below Step 1 Install an iRIS 2400 module to the IPMI module socket refer to Section 4 5...

Страница 85: ...our two digit hexadecimal numbers are the IP address Convert the hexadecimal numbers to decimal numbers Step 2 On the remote management console open a web browser Enter the managed system IP address i...

Страница 86: ...70 Figure 4 20 IEI iMAN Web GUI NOTE To understand how to use the IEI iMAN Web GUI please refer to the iRIS 2400 Web GUI user manual which can be obtained from IEI Resource Download Center The user ma...

Страница 87: ...SPCIE C2260 i2 PICMG 1 3 CPU Card Page 71 Chapter 5 5 BIOS...

Страница 88: ...Press the DEL or F2 key as soon as the system is turned on or 2 Press the DEL or F2 key when the Press DEL or F2 to enter SETUP message appears on the screen If the message disappears before the DEL...

Страница 89: ...avigation Keys 5 1 3 Getting Help When F1 is pressed a small help window describing the appropriate keys to use and the possible selections for the highlighted item appears To exit the Help Window pre...

Страница 90: ...Passwords Save Exit Selects exit options and loads default settings Server Mgmt Configures system event log and BMC network parameters The following sections completely describe the configuration opt...

Страница 91: ...rocessor ID 306c2 Stepping B0 Number of Processors 4Core s 8Thread s Microcode Revision ffff0006 GT Info GT2 800 MHz IGFX VBIOS Version 2178 Memory RC Version 1 6 2 1 Total Memory 4096 MB DDR3 Memory...

Страница 92: ...r configurable fields System Date xx xx xx Use the System Date option to set the system date Manually enter the day month and year System Time xx xx xx Use the System Time option to set the system tim...

Страница 93: ...elp F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 15 1236 Copyright C 2012 American Megatrends Inc BIOS Menu 2 Advanced 5 3 1 ACPI Settings The ACPI Settings menu BIOS Menu...

Страница 94: ...ower to the RAM is maintained The computer returns slower to a working state but more power is saved 5 3 2 RTC Wake Settings The RTC Wake Settings menu BIOS Menu 4 enables the system to wake at the sp...

Страница 95: ...option appears allowing you to enable to disable the system to wake every day at the specified time Besides the following options appear with values that can be selected Wake up date Wake up hour Wak...

Страница 96: ...t show Security Device TCG EFI protocol and INT1A interface will not be available Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exi...

Страница 97: ...L1 Data Cache 32 kB x 4 L1 Code Cache 32 kB x 4 L2 Cache 256 kB x 4 L3 Cache 8192 kB Hyper threading Enabled Active Processor Cores All Intel Virtualization Technology Disabled EIST Enabled Intel TXT...

Страница 98: ...Technology Disabled Use the Intel Virtualization Technology option to enable or disable virtualization on the system When combined with third party software Intel Virtualization technology allows sev...

Страница 99: ...creen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 15 1236 Copyright C 2012 American Megatrends Inc BIOS Menu 7 SATA Con...

Страница 100: ...Intel R Rapid Start Technology Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 15 1236 Copyright C 2012 Ameri...

Страница 101: ...If enabled this requires additional firmware in the SPI device Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version...

Страница 102: ...1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 15 1236 Copyright C 2012 American Megatrends Inc BIOS Menu 10 USB Configuration USB Devices The USB Devices fiel...

Страница 103: ...2 American Megatrends Inc Advanced F81866 Super IO Configuration F81866 Super IO Chip F81866 Serial Port 1 Configuration Serial Port 2 Configuration Serial Port 3 Configuration Serial Port 4 Configura...

Страница 104: ...Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 15 1236 Copyright C 2012 American Megatrends Inc BIOS Menu 12 Serial Port n Configuration Menu 5 3 9 1 1 Serial Port 1 Configuration Serial...

Страница 105: ...LT Enable the serial port Change Settings Auto Use the Change Settings option to change the serial port IO port address and interrupt address Auto DEFAULT The serial port IO port address and interrupt...

Страница 106: ...2D0h IRQ 11 Serial Port I O port address is 2D0h and the interrupt address is IRQ11 IO 2D0h IRQ 10 11 Serial Port I O port address is 2D0h and the interrupt address is IRQ10 11 IO 2D8h IRQ 10 11 Seria...

Страница 107: ...Port I O port address is 2D8h and the interrupt address is IRQ10 11 IO 2C0h IRQ 10 11 Serial Port I O port address is 2C0h and the interrupt address is IRQ10 11 IO 2C8h IRQ 10 11 Serial Port I O port...

Страница 108: ...2 IrDA Configuration Use the IrDA Configuration menu BIOS Menu 13 to configure the infrared port Aptio Setup Utility Copyright C 2012 American Megatrends Inc Advanced IrDA Configuration Serial Port En...

Страница 109: ...IRQ 10 11 Infrared port I O port address is 2D8h and the interrupt address is IRQ10 11 IO 2C0h IRQ 10 11 Infrared port I O port address is 2C0h and the interrupt address is IRQ10 11 IO 2C8h IRQ 10 11...

Страница 110: ...zed Defaults F4 Save Exit ESC Exit Version 2 15 1236 Copyright C 2012 American Megatrends Inc BIOS Menu 14 Parallel Port Configuration Menu Parallel Port Enabled Use the Parallel Port option to enable...

Страница 111: ...10 F81866 H W Monitor The F81866 H W Monitor menu BIOS Menu 15 contains the fan configuration submenu and displays the system temperature and CPU fan speed Aptio Setup Utility Copyright C 2012 Americ...

Страница 112: ...hat are monitored are System Temperatures o CPU Temperature o System Temperature Fan Speeds o CPU Fan Speed o System Fan Speed Voltages o V_CPU_CORE o 5V o 12V o DDR o 5VSB o 3 3V o 3 3VSB 5 3 10 1 Sm...

Страница 113: ...2 15 1236 Copyright C 2012 American Megatrends Inc BIOS Menu 16 Smart Fan Mode Configuration CPU_FAN1 Smart Fan Control SYS_FAN1 Smart Fan Control Auto Mode Use the CPU_FAN1 Smart Fan Control SYS_FAN...

Страница 114: ...Settings COM4 Console Redirection Disabled Console Redirection Settings COM5 Console Redirection Disabled Console Redirection Settings COM7 BMC Disabled Console Redirection Port IS Disabled iAMT SOL C...

Страница 115: ...nes may require lower speeds 9600 Sets the serial port transmission speed at 9600 19200 Sets the serial port transmission speed at 19200 57600 Sets the serial port transmission speed at 57600 115200 D...

Страница 116: ...ULT Sets the number of stop bits at 1 2 Sets the number of stop bits at 2 5 3 12 iEi Feature Use the iEi Feature menu BIOS Menu 18 to configure One Key Recovery function Aptio Setup Utility Copyright...

Страница 117: ...ystem Agent SA configuration menus WARNING Setting the wrong values for the Chipset BIOS selections in the Chipset BIOS menu may cause the system to malfunction Aptio Setup Utility Copyright C 2012 Am...

Страница 118: ...evious Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 15 1236 Copyright C 2012 American Megatrends Inc BIOS Menu 20 PCH IO Configuration Restore AC Power Loss Last State Use the Restore...

Страница 119: ...PCIe x16 slot as one PCIe x8 or two PCIe x4 USB SW1 Power 5V DUAL Use the USB SW1 Power BIOS option to configure the USB power source for the external USB 3 2 Gen 1 ports 5V Sets the USB power source...

Страница 120: ...t Version 2 15 1236 Copyright C 2012 American Megatrends Inc BIOS Menu 21 PCI Express Configuration 5 4 1 1 1 PCI E Mini Card PCIEX4 Slot Use the PCI E Mini Card PCIEX4 Slot menu BIOS Menu 22 to confi...

Страница 121: ...evice option to enable or disable detecting if a non compliance PCI Express device is connected to the PCI Express port Disabled Disables to detect if a non compliance PCI Express device is connected...

Страница 122: ...nally Enabled Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 15 1236 Copyright C 2012 American Megatrends In...

Страница 123: ...to enable VT d function on MCH Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 15 1236 Copyright C 2012 Amer...

Страница 124: ...xit Version 2 15 1236 Copyright C 2012 American Megatrends Inc BIOS Menu 25 Graphics Configuration Primary Display Auto Use the Primary Display option to select the primary graphics controller the sys...

Страница 125: ...e activated during POST This has no effect if external graphics present Secondary boot display selection will appear based on your selection VGA modes will be supported only on primary display Select...

Страница 126: ...Optimized Defaults F4 Save Exit ESC Exit Version 2 15 1236 Copyright C 2012 American Megatrends Inc BIOS Menu 27 NB PCIe Configuration PEG0 Gen X Auto Use the PEG0 Gen X option to select the support t...

Страница 127: ...e PCI Express device is connected to the PCI Express port 5 4 2 3 Memory Configuration Use the Memory Configuration submenu BIOS Menu 28 to view memory information Aptio Setup Utility Copyright C 2012...

Страница 128: ...SC Exit Version 2 15 1236 Copyright C 2012 American Megatrends Inc BIOS Menu 29 Boot Bootup NumLock State On Use the Bootup NumLock State BIOS option to specify if the number lock setting must be modi...

Страница 129: ...to set the Option ROM display mode Force BIOS DEFAULT Sets display mode to force BIOS Keep Current Sets display mode to current Launch PXE OpROM Disabled Use the Launch PXE OpROM option to enable or...

Страница 130: ...en this is a power on password and must be entered to boot or enter Setup In Setup the User will have Administrator rights The password length must be Minimum length 3 Maximum length 20 Administrator...

Страница 131: ...Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 15 1236 Copyright C 2012 American Megatrends Inc BIOS Menu 31 Save Exit Save Changes and Reset Use the Save Changes and Re...

Страница 132: ...rameters Aptio Setup Utility Copyright C 2012 American Megatrends Inc Main Advanced Chipset Boot Security Save Exit Server Mgmt BMC Self Test Status System Event Log BMC network configuration Press En...

Страница 133: ...le all features of System Event Logging during boot Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 15 1236 C...

Страница 134: ...thing when SEL is full Erase Immediately Erase SEL immediately when SEL is full Log EFI Status Codes Both Use the Log EFI Status Codes option to select an option to log EFI status codes Disabled Disab...

Страница 135: ...MC Unspecified option will not modify any BMC network parameters during BIOS phase Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Ex...

Страница 136: ...Select to configure LAN channel parameters dynamically by BMC Dynamic Loaded by BIOS Select to configure LAN channel parameters dynamically by BIOS Dynamic BMC running Other Protocol Select to configu...

Страница 137: ...SPCIE C2260 i2 PICMG 1 3 CPU Card Page 121 6 Software Drivers Chapter 6...

Страница 138: ...s Enter to find all the relevant software utilities and documentation Figure 6 1 IEI Resource Download Center 6 2 Driver Download To download drivers from IEI Resource Download Center follow the steps...

Страница 139: ...e or double click an individual item to find its driver file and click the file name to download NOTE To install software from the downloaded ISO image file in Windows 8 8 1 or 10 double click the ISO...

Страница 140: ...SPCIE C2260 i2 PICMG 1 3 CPU Card Page 124 Appendix A A Regulatory Compliance...

Страница 141: ...interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are d...

Страница 142: ...SPCIE C2260 i2 PICMG 1 3 CPU Card Page 126 B Product Disposal Appendix B...

Страница 143: ...s classified as electronic device in terms of the European Directive 2012 19 EU WEEE and must not be disposed of as domestic garbage EU wide legislation as implemented in each Member State requires th...

Страница 144: ...SPCIE C2260 i2 PICMG 1 3 CPU Card Page 128 Appendix C C BIOS Options...

Страница 145: ...Enabled 82 SATA Controller s Enabled 83 SATA Mode Selection IDE 83 Intel R Rapid Start Technology Disabled 84 Intel AMT Enabled 85 Un Configure ME Disabled 85 USB Devices 86 Legacy USB Support Enable...

Страница 146: ...Function ERP Disabled 102 PCIEX16 Power 1 x16 PCIE 103 USB SW1 Power 5V DUAL 103 USB SW2 Power 5V DUAL 103 PCIe Speed Gen1 105 Detect Non Compliance Device Enabled 105 Azalia HD Audio Enabled 106 VT...

Страница 147: ...set 115 Discard Changes and Reset 115 Restore Defaults 115 Save as User Defaults 115 Restore User Defaults 116 SEL Components Enabled 117 Erase SEL No 117 When SEL is Full Do Nothing 118 Log EFI Statu...

Страница 148: ...SPCIE C2260 i2 PICMG 1 3 CPU Card Page 132 Appendix D D Digital I O Interface...

Страница 149: ...rally control signals that control the on off circuit of external devices or TTL devices Data can be read or written to the selected address to enable the DIO functions NOTE For further information pl...

Страница 150: ...setting the digital port as input INT 15H AL low byte value AH 6FH Sub function AL 9 Set the digital port as OUTPUT BL Digital I O input value D 3 Assembly Language Sample 2 MOV AX 6F09H setting the...

Страница 151: ...SPCIE C2260 i2 PICMG 1 3 CPU Card Page 135 Appendix E E Watchdog Timer...

Страница 152: ...ll INT 15H is used to control the Watchdog Timer INT 15H AH 6FH Sub function AL 2 Sets the Watchdog Timer s period BL Time out value Its unit second is dependent on the item Watchdog Timer unit select...

Страница 153: ...e the system resets EXAMPLE PROGRAM INITIAL TIMER PERIOD COUNTER W_LOOP MOV AX 6F02H setting the time out value MOV BL 30 time out value is 48 seconds INT 15H ADD THE APPLICATION PROGRAM HERE CMP EXIT...

Страница 154: ...SPCIE C2260 i2 PICMG 1 3 CPU Card Page 138 Appendix F F Intel Matrix Storage Manager...

Страница 155: ...ltiple hard drives appears to an operating system as a contingent storage space The operating system will not be able to distinguish the physical disk drives contained in a RAID configuration F 1 1 Pr...

Страница 156: ...below Step 1 Connect SATA drives to the system Connect two or more SATA drives to the system Make sure the drives have the same capacity are the same type and have the same speed NOTE Make sure the SA...

Страница 157: ...ng the Operating System to the RAID Array To install the operating system to the RAID array some extra steps are necessary during the installation process Step 1 Prepare a RAID driver floppy disk on a...

Страница 158: ...SPCIE C2260 i2 PICMG 1 3 CPU Card Page 142 Appendix G G Error Beep Code...

Страница 159: ...was not found 4 Recovery failed 4 S3 Resume failed 7 Reset PPI is not available G 2 DXE Beep Codes Number of Beeps Description 1 Invalid password 4 Some of the Architectural Protocols are not availab...

Страница 160: ...SPCIE C2260 i2 PICMG 1 3 CPU Card Page 144 Appendix H H Hazardous Materials Disclosure...

Страница 161: ...ominated Diphenyl Ethers PBDE Bis 2 ethylhexyl phthalate DEHP Butyl benzyl phthalate BBP Dibutyl phthalate DBP Diisobutyl phthalate DIBP Housing O O O O O O O O O O Display O O O O O O O O O O Printed...

Страница 162: ...PU Card Page 146 H 2 China RoHS RoHS RoHS Pb Hg Cd CR VI PBB PBDE O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O SJ T11364 2014 GB T26572 2011 X SJ T...

Отзывы: