Command/Action
Keys to Enter/Details
Command 10.
Assign Virtual
Outputs to Physical
Outputs
10 # virtual output # physical output # *
*
Virtual Output List
Physical Output List
0 - No mapping
1 - Relay 1 (Main Relay)
(physical output unused)
1 - Lock
2 - Relay 2 (K2)
2 - Alarm Shunt
3 - Relay 3 (K3)
3 - Propped Door
4 - Relay 4 (K4)
4 - Forced Door
9 - Audio Alert #1
5 - OUT2
10 - Audio Alert #2
6 - OUT3
7 - OUT4
8 - OUT5
13 - Duress
14 - Panic
15 - Keypad Active
Defaults—
The
212eM/242eM
keypad comes
programmed with
the following default
output assignments:
The Lock Output is assigned to Relay 1, the
Alarm Shunt Output to Relay 2, the Propped
Door Output to Relay 3, and the Forced
Door Output to Relay 4.
7.2.1 Virtual Outputs
Virtual Output
Description/Details
Lock
This output is used for your locking device.
Alarm Shunt
This is used to shunt out an existing alarm
panel. It activates with the lock output and
de-energizes one second after the lock time
expires.
Propped Door
This output activates after entering a valid
user code only if the door position switch is
left open longer than the programmed
propped door time.
IEI 212eM/242eM Standalone Installation/Programming Manual
Document # 6174000, Rev. 1.1
17