NOTE: You MUST wire a normally closed door switch, as
shown in Figure 6, for these functions to work properly.
1.
(
Wiring the alarm shunt
) Using P1 (K2), connect the blue
wire (common) to common on the door switch. Connect the
green wire (normally open) to the normally closed contact on
the door switch.
2.
(
Wiring the propped door alarm
) Using P2 (K3), connect the
green wire (normally open) to the positive on the alarm
device. Connect the blue wire (common) to the positive on
the power supply. Connect the negative on the alarm device
to the negative on the power supply.
3.
(
Wiring the forced door alarm
) Using P3 (K4), connect the
green wire (normally open) to the positive on the alarm
device. Connect the blue wire (common) to the positive on
the power supply. Connect the negative on the alarm device
to the negative on the power supply.
Figure 12 Wiring an Integrated Accessory Relay Board
IEI 212eM/242eM Standalone Installation/Programming Manual
14
Document # 6174000, Rev. 1.1