background image

 

2

 

General matters 

2.1

 

Scope of application

 

This product is part of Group II, which targets gas and steam in general workplaces and 
chemical plants, and can be installed and used in Zone 2. 
 

2.2

 

Supply Range

 

All Supply Inclusion Model names 

2.2.1

 

Supply not included 

2.2.1.1

 

Foundation work, installation work 

2.2.1.2

 

Acquisition, handling, and storage in the field 

2.2.1.3

 

Access to external wires and grounds (including EARTH LUG) 

 

2.3

 

Product transportation 

2.3.1

 

Transport 

2.3.1.1

 

Packaging method and packing specification 

2.3.1.1.1

 

After removing foreign substances from the inside and outside of the product, 
it was completely cleaned and dried, and the parts that were not handled in a 
proper manner were treated in a proper manner. 

2.3.1.1.2

 

Packaging shall be rigidly aligned with the size and weight of the contents, and 
shall be properly protected against rust and corrosion by using materials that 
can be buffered, such as air caps and newspapers. 

 

2.3.1.2

 

Transport method 

2.3.1.2.1

 

In principle, packaged products shall be delivered directly by the manufacturer 
or  by  means  of  transportation  designated  by  the  manufacturer,  and  parcels 
shall be used in island areas and islands mountainous areas. 

2.3.1.2.2

 

When transporting a product, if it is thrown or piled high due to the weight of 
the product itself, it may damage the product, so it must be transported using 
appropriate protective measures or equipment. 

 

¾

 

We  are  packing  this  product  with  utmost  care,  but  there  may  be  loss  of  contents  or 
damage in the transportation process, so please check the condition of the contents after 
you take over the product. 

¾

 

If there are any defects in the contents, please contact us immediately for action. 

¾

 

Please contact the customer service center if there is a loss, damage, or deterioration of 
quality due to improper packaging by the manufacturer. 

 

Содержание FI-ST4 Series

Страница 1: ...duct Temperature Sensor User s Guide REV 0 Date 2021 03 21 Document number FI 2021 0321 FINE ENG CO Address 507Ho E Dong 30 SongdoMirae ro Yeonsu gu Incheon Metropolitan City Korea TEL 032 433 2697 Fa...

Страница 2: ...5 2 1 Scope of application 5 2 2 scope of supply 5 2 3 Product transportation 5 2 4 Installing the product 6 2 5 Machine Operation and Precautions 7 3 Maintenance and Management 8 3 1 Inspection and...

Страница 3: ...T6 T4 T6 T4 temperature grade applied according to the temperature range of the measured fluid 1 1 5 1 Barometric pressure 80kPa 110kPa 1 1 5 2 Ambient temperature 20 50 65 100 1 1 5 3 Humidity not m...

Страница 4: ...afety certification 1 3 1 1 Product name Temperature Sensor 1 3 1 2 Model name FI ST4 S M PT PT Thread Type Meter Thread Type Standard Type Released sequence Type of sensor Company English abbreviatio...

Страница 5: ...s and shall be properly protected against rust and corrosion by using materials that can be buffered such as air caps and newspapers 2 3 1 2 Transport method 2 3 1 2 1 In principle packaged products s...

Страница 6: ...When installing an explosion proof electrical device the following specifications shall be compared to the technical specifications to verify that they are consistent a Rated voltage and current rate...

Страница 7: ...and components installed inside and outside and provide the operator with knowledge and training prior to installation to ensure safe installation 2 4 2 2 7 During the installation process of this pr...

Страница 8: ...ular inspection 3 1 3 3 Samples shall be inspected visually closely or in detail and the size and composition of all samples shall be determined according to the purpose of the inspection 3 1 3 4 Cont...

Страница 9: ...e or damage and install the product in accordance with appropriate working procedures 3 2 3 In particular this product must be careful because cracks may occur on the sealing part of the sith and do n...

Страница 10: ...9 3 2 7 Regular inspection items in Table 1 shall be classified according to the procedures in Figure 1 Figure 1 Regular inspection procedure...

Страница 11: ...uately protected from corrosion weather vibration and other adverse conditions o o o o o o o o o 3 The electrical insulator is clean and dry o o When inspecting each electric device with a explosion p...

Страница 12: ...mage caused by natural disasters fire salt earthquake storm and flood lightning artificial impact etc 3 3 2 5 A S Free service and contact information TEL 82 32 433 2697 FAX 82 32 433 2698 3 3 2 6 If...

Страница 13: ...0 0 15 0 002 x t 0 3 0 005 x t 200 0 55 1 3 100 0 35 0 8 0 0 15 0 3 100 0 35 0 8 200 0 55 1 3 300 0 75 1 8 400 0 95 2 3 500 1 15 2 8 600 1 35 3 3 Interdial line and standard winding method Wiring Meth...

Отзывы: