p.12
Initialization
You can turn on/off the indicators according to the I/O settings of the controller, which can
be applied to various situations. For more information about the I/O settings of the
controller, refer to the user manual of the controller.
To control the orange indicator, connect the gray line to NC of the controller.
1.5
Buzzer Control
Connect the buzzer control input line (blue) to the NO port of the controller relay output,
and GND to the COM port.
You can configure the I/O settings of the controller so that it beeps. If the product continues
to beep, it means that the buzzer control is working properly.
The controller can use the I/O settings to set the buzzer control so that it sounds an
additional beep for authorized or unauthorized access upon user authentication.
Furthermore, you can make various modifi cations according to the different I/O settings of
the controller.
For more information about the I/O settings of the controller, refer to the user manual of
the controller.
Card reading is not available while the buzzer control is sounding the buzzer.
1.6
Tamper Control
You can set the signal that you want to output if the device is dismantled forcibly.
Connect the COM port (Pink line) of the product’s tamper switch to GND; connect the NC
port (Light yellow) of the tamper switch to the input port of the controller. If the tamper of
the reader operates, the controller produces an input signal and generates the
corresponding output depending on the controller setting.