I/O time setup
100RV
p.31
• You can specify a two-digit time from 00 to 99 seconds.
By default, only the alarm relay operates for “02” seconds in normal and Secure modes.
Other output ports that are not specifi ed for the output mode will not be
activated.
For instance, if you set the output mode to [5][2] and assign the operation time
for each output device by following the steps 4, 5, and 6 above, only the alarm
relay will operate.
3
To specify the DURESS TTL output
If you enter the Duress code and present a registered card, the TTL output operates. Specify
the TTL operation time for this purpose. (For the Duress code, refer to
1 DURESS alarm
.)
1.
Present the Master Card to the device.
2.
Press Button
and Button
in sequence and press
.
3. Specify the two-digit TTL output time (unit: second) and press
.
• The default is set to “03” second.
You can specify a time from 00 to 99 seconds.
4
To specify the alarm output for an input error of the
door contact sensor
You can specify the output port and operation time if an error occurs from the Door Contact
Sensor.
You must have specifi ed the operation time of the Door Contact Sensor. (Refer to “To
specify the operation time of the Door Contact Sensor” on page 25.)
1.
Present the Master Card to the device.