Basic setup
100RV
p.27
2. Press Button
and Button
in sequence and press
.
3. Enter the two-digit operation time (unit: second) and press
.
• The default is set to “20” second.
• You can specify from 10 to 99.
7
To specify the alarm output port for the dismantled
device
Specify the alarm type for the dismantled device. The alarm rings from the dismantlement of
the device to the authentication of the Master Card or a registered card.
1.
Present the Master Card to the device.
2.
Press Button
and Button
in sequence and press
.
3.
Provide the alarm output port and press
.
• The default is set to “02” (alarm).
For the alarm output port settings, refer to
Output port table
.
• The alarm for the dismantled device occurs regardless of the operation mode of
either Normal or Secure so you simply specify the operation port only. (To specify the
operation port, refer to
the operation port settings in the Output Port Setting Table
.)
8
To open or close the entry door
Follow the step below If you want to keep the door open regardless of the authentication
process using the Master Card or PIN.
1.
Present the Master Card to the device.
2.
Press Button
and Button
in sequence and press
.
• To release opening the door, repeat Step 1 above, select the <
> buttons and
Содержание 100RV