p.12
Installation and external connection
100RV
Door open (POWER FAIL SAFE) when the power is disconnected from the door lock
(Door Relay)
1.
Connect the relay COM line (gray with red stripes for locking the door) to DC +12V.
2.
Connect the relay NC line (blue with white stripes for locking the door) to the plus(+)
line of the door lock.
3.
Connect the minus (-) line of the door lock to GND (-).
Door close (POWER FAIL SECURE) when the power is disconnected from the door
lock (Door Relay)
1.
Connect the relay COM line (gray with red stripes for locking the door) to DC +12V.
2. Connect the relay NO line (white with red stripes for locking the door) to the plus (+)
line of the door lock.
3.
Connect the minus (-) line of the door lock to GND (-).
Alarm Connection (Alarm Relay)
1.
Connect the relay COM (white for the alarm device) to DC +12V.
2.
Connect the relay NO line (purple for the alarm device) to the plus (+) line of the alarm
device.
3. Connect the minus (-) line of the alarm device to GND (-).
Chime Bell Connection (the chime bell operated by TTL-level signal must be installed
in advance.)
1.
Connect the chime bell line (brown with white stripes) of the controller to DC +5V.
2.
Connect the GND line of the power supply unit to GND (-) of the chime bell.
3. Press
to activate EthNeT chime bell.
Содержание 100RV
Страница 1: ...User Manual 100RV Standalone RFID Access Controller ...
Страница 11: ...p 6 Product introduction 100RV 3 At a glance ...
Страница 40: ...I O time setup 100RV p 35 The default is set to disabled ...
Страница 63: ...p 58 Warranty Policy and Limitation of Liability 100RV ...
Страница 65: ......