RapidIO Port-Write Timeout Control Register
This register defines port-write time-out value. Whenever a port-write is pending, this timer begins
counting. When this timer expires and the port write has not yet been cleared, another port-write is sent
and the timer begins counting again.
Register name: RIO_PW_TIMEOUT
Reset value: 0x0000_0000
Register offset: 1AC14
Bits
0
1
2
3
4
5
6
7
00:07
PW_TIMER
Reserved
08:15
Reserved
16:23
Reserved
24:31
Reserved
Bits
Name
Description
Type
Reset
Value
0:3
PW_TIMER
Port-write Timer
This field defines the time period to repeat sending an error reporting
port-write request for software assistance. The timer is stopped by
software writing to the error detect registers.
The timeout value is computed by = {[167772160 ns x
pw_timer_value (in decimal)] + 2x(10 ns)}, where 10 ns = clock cycle
period of the AMBA clk
Register Bus frequency - 100 MHz
0000 = Disabled and a port-write is sent once per event.
0001 = 167.7ms
0010 = 335.5ms
0100 = 671.1ms
1000 = 1.34s
1111 = 1.3us (Debug only)
Other values are reserved.
R/W
0
4:31
Reserved
N/A
R
0
Содержание Tsi578
Страница 1: ...IDT Tsi578 Serial RapidIO Switch User Manual June 6 2016 Titl ...
Страница 20: ...About this Document 20 Tsi578 User Manual June 6 2016 Integrated Device Technology www idt com ...
Страница 102: ...4 Internal Switching Fabric Packet Queuing 102 Tsi578 User Manual June 6 2016 Integrated Device Technology www idt com ...
Страница 228: ...11 Signals Pinlist and Ballmap 228 Tsi578 User Manual June 6 2016 Integrated Device Technology www idt com ...
Страница 504: ...B Clocking P_CLK Programming 504 Tsi578 User Manual June 6 2016 Integrated Device Technology www idt com ...
Страница 526: ...Index 526 Tsi578 User Manual June 6 2016 Integrated Device Technology www idt com ...