12. Serial RapidIO Registers > RapidIO Error Management Extension Registers
292
Tsi578 User Manual
June 6, 2016
Integrated Device Technology
www.idt.com
12.7.7
RapidIO Logical and Transport Layer Control Capture CSR
This register contains error information, specifically the message type and subtype field values for
failed transactions. It is locked when a Logical/Transport error is detected and the corresponding
enable bit is set.
The Ftype value should always be eight for a maintenance packet. The TTYPE value always reflects
the four bits following the FTYPE field in the packet. Note that for switches, the errors detected are
limited to maintenance packets (maintenance requests, maintenance responses, and port writes) with a
hop count of 0. No other packets reach the logical layer of a switch.
Note that this register is not updated when a correctly formatted maintenance request fails.
Register name: RIO_LOG_ERR_CTRL_INFO
Reset value: 0x0000_0000
Register offset:101C
Bits
0
1
2
3
4
5
6
7
00:07
FTYPE
TTYPE
08:15
Reserved
16:23
Reserved
24:31
Reserved
Bits
Name
Description
Type
Reset
Value
0:3
FTYPE
Format type associated with the error
R/W
0
4:7
TTYPE
Transaction type associated with the error
R/W
0
8:31
Reserved
N/A
R
0
A value of 0x00000000 must be written to this register to clear it.
Содержание Tsi578
Страница 1: ...IDT Tsi578 Serial RapidIO Switch User Manual June 6 2016 Titl ...
Страница 20: ...About this Document 20 Tsi578 User Manual June 6 2016 Integrated Device Technology www idt com ...
Страница 102: ...4 Internal Switching Fabric Packet Queuing 102 Tsi578 User Manual June 6 2016 Integrated Device Technology www idt com ...
Страница 228: ...11 Signals Pinlist and Ballmap 228 Tsi578 User Manual June 6 2016 Integrated Device Technology www idt com ...
Страница 504: ...B Clocking P_CLK Programming 504 Tsi578 User Manual June 6 2016 Integrated Device Technology www idt com ...
Страница 526: ...Index 526 Tsi578 User Manual June 6 2016 Integrated Device Technology www idt com ...