This section includes a list of frequently asked questions for problems you may encounter with your electrisave™. If your
electrisave™ is not operating as you think it should, check here before arranging for servicing.
NOTE
After resetting the main unit receiver it may take up to 2 minutes to re-establish the communications link. This can be
expedited by pressing the “CHECK” button on the remote transmitter for 2 seconds (beep) to force transmissions every 2
secs
Dimensions
Main Unit- Receiver
Width x Height x Depth
107 W x 117 H x 30 D mm
Weight
160 g
Remote Transmitter
Width x Height x Depth
78 W x 113 H x 40 D mm
Weight
110 g
Power On Factory Default Settings:
AC voltage
240v
1kg Co2
1 kW/hr
GHG unit (greenhouse gas) Kg/Hour
GHG conversion
1 kg Co2 = 1 kW/hr
Tariff charge (cost-per-hour)
12.0 cents per kWh
Temperature unit
°C
Currency
$ and cent
Hi alarm
$2.00/hour, on
Receiving cycle
MAX 6 second
Display Mode
Cost rate display
16
TROUBLESHOOTING GUIDE
SPECIFICATIONS
Problem
Symptom
Check this
Remedy
No power or no
reading
“
----
“ reading
Power will not turn on or no
display reading on LCD screen
“
----
“ display readings on LCD
screen
Remote and Main Unit are out
of synchronisation or
transmission has been broken
Reset both units
“0.00“ reading
Current not detected
No power being used or
sensor incorrectly installed.
Check sensor is correctly installed
or Call Electrician to check Alarm
Alarm
“
----
“ reading in Alarm mode
Alarm disabled
Activate alarm
“----” flashing
Automatic search underway
-
- Allow search to run to
completion
Main unit receiver
receives data from
another remote
transmitter
Display does not respond as
expected
Incorrect transmitter detected
during installation or following
battery replacement or “reset”
Refer to installation instructions
Batteries are exhausted
Batteries are inserted
incorrectly
Replace with new batteries
Insert the batteries correctly
(
Batteries
)